4.2 Print Head Pressure Adjustment Knob

4.2 Print Head Pressure Adjustment Knob

There are two conditions that will need to adjust the print head pressure.

1.Print with thick media

If the media thickness is larger than 0.19 mm, the larger pressure is required to get good quality printout.

2.Print with narrow media

If the media width is less than 4 inch wide the print head pressure will need to be adjusted to avoid ribbon wrinkle

There are 5 levels of pressure for adjustment. Level 1 is the minimum pressure and level 5 is the maximum pressure.

For example, if the label width is 4 inch, adjust both print head pressure adjustment knobs to the same level. If the label is less than 2 inch wide, increase the left side print head pressure by rotating the adjustment knob clockwise and decrease the right side pressure by rotating the adjustment knob counter-clockwise to level 1.