SECTION 2: GAS REQUIREMENTS

NATURAL GAS REQUIREMENTS -

Inlet Connection: 1/2" NP with 3/8" NPT reducer adapter. Supply Pressure: 6" to 14" W.C.

Manifold Pressure: 5" W.C.

PROPANE GAS REQUIREMENTS -

Inlet Connection: 1/2" NP with 3/8" NPT reducer adapter. Supply Pressure: 11" to 14" W.C.

Manifold Pressure: 10" W.C.

! !

IMPORTANT: A manual gas shut off valve must be installed external to the appliance, in a location accessible with the unit installed in the enclosure. Make sure the valve is turned off prior to connecting the appliance.

IMPORTANT: Un robinet manuel d'isolement doit étre installé à l’extérieur de l’appareil, dans un emplacement accessible avec l’unité installée dans la module. Assurez-vous que le robinet est fermé avant de brancher l’appareil.

FIGURE 1 – PROPANE HOOK-UP

FIGURE 2 – NATURAL GAS HOOK-UP

 

 

Bottom of

unit

 

 

Coupling

1/2"

NPT fitting

threading compound on

 

 

these threads must be

L.P. Regulator hose

resistant

to LP

gas

assembly 10" W.C.

 

 

 

Page 3