SECTION 4: ELECTRICAL REQUIREMENTS
AND GROUNDING INSTRUCTIONS
CAUTION |
|
|
| CAUTION |
|
|
|
|
|
Installation of electrical supply circuit should be done by a qualified electrician in accordance with local codes and ordinances. In the absence of local codes or ordinances, the supply should be installed in accordance with the National Electric Code ANSI/NFPA No. 70, current issue, or Canadian Electric Code C22.1 Part 1.
The Thermador® Char Glo® barbecues use an electronic ignition system that requires a 120 VAC, 15A, 60 Hz power supply. A properly grounded duplex outlet must be provided adjacent to the lower left rear corner of the unit. See Figure 5A (below).
A properly grounded duplex outlet made for outdoor applications should also be provided above the level of the cooking surface on the left side of the unit. This outlet is required for connection of the rotisserie motor. See Figure 3 (Page 5).
WARNING
Electrical Grounding Instructions
This outdoor cooking gas appliance is equipped with a
AVERTISSEMENT
Instruction pour la mise
a la terre electrique
Cet appareil est muni d’une fiche a trots broches (mise a la terre) afin de vous proteger des chocs et doit etre branche dire~ement dans une prise de courant a trots broches adequatement mise a la tem. II ne faut pas couper ou enlever la broche de mise a la tem de cette fiche.
Figure 5A
BARBECUE
Page 7