Introduction
Before using your appliance, be sure to read this manual. Pay special attention to the Important Safety Instructions located at the beginning of the manual.
This manual provides the proper care and use instructions for two styles of THERMADOR PROFESSIONAL® PH Series wall hoods:
•PHxxGS — 27” (686 mm) in depth, with widths of 36” (914 mm), 42” (1067 mm), 48” (1219 mm), and 54” (1372 mm). This model series features brushed
•PHxxHS — 24” (610 mm) in depth, with widths of 30” (762 mm), 36” (914 mm), and 48” (1219 mm). This model series features brushed
All hoods require the choice of a Remote, Inline, or Integral Blower. Use only THERMADOR® blowers with THERMADOR ventilation hoods. All blower models are sold separately. See Table 1, Blower & Circuit Breaker Ratings for recommended blowers. Contact Customer Service for additional options.
All Hood models are rated for 120 VAC, using a 15 amp or 20 amp circuit breaker; see the Installation Manual for more details.
When connected to a
Blower | SKU | CFM | Voltage (AC) | Blower Current | Circuit Breaker | |
(AMPS) | (AMPS) | |||||
|
|
|
| |||
|
|
|
|
|
| |
Remote Blower 600 CFM | VTR630D | 600 | 120 | 4.2 | 15 | |
|
|
|
|
|
| |
Remote Blower 1000 CFM | VTR1030D | 1000 | 120 | 5.7 | 15 | |
|
|
|
|
|
| |
Remote Blower 1300 CFM | VTR1330E | 1300 | 120 | 8.5 | 20* / 15** | |
|
|
|
|
|
| |
Inline Blower 600 CFM | VTI610D | 600 | 120 | 4.2 | 15 | |
|
|
|
|
|
| |
Inline Blower 1000 CFM | VTI1010D | 1000 | 120 | 5.7 | 15 | |
|
|
|
|
|
| |
Integral Blower 600 CFM | VTN630C | 600 | 120 | 2.7 | 15 | |
|
|
|
|
|
| |
Integral Blower 1000 CFM | VTN1030C | 1000 | 120 | 5.4 | 15 | |
|
|
|
|
|
|
* 20 Amp circuit breaker required when using the VTR1330E Remote Blower with a 27” Pro Wall Hood. ** 15 Amp circuit breaker required when using the VTR1330E Remote Blower with a 24” Pro Wall Hood.
Table 1: Blower & Circuit Breaker Ratings