Introduction

Introduction

Before using your appliance, be sure to read this manual. Pay special attention to the Important Safety Instructions located at the beginning of the manual.

This manual provides the proper care and use instructions for two styles of THERMADOR PROFESSIONAL® PH Series wall hoods:

PHxxGS — 27” (686 mm) in depth, with widths of 36” (914 mm), 42” (1067 mm), 48” (1219 mm), and 54” (1372 mm). This model series features brushed stainless-steel canopy with halogen lamps and heat lamps.

PHxxHS — 24” (610 mm) in depth, with widths of 30” (762 mm), 36” (914 mm), and 48” (1219 mm). This model series features brushed stainless-steel canopy with halogen lamps.

All hoods require the choice of a Remote, Inline, or Integral Blower. Use only THERMADOR® blowers with THERMADOR ventilation hoods. All blower models are sold separately. See Table 1, Blower & Circuit Breaker Ratings for recommended blowers. Contact Customer Service for additional options.

All Hood models are rated for 120 VAC, using a 15 amp or 20 amp circuit breaker; see the Installation Manual for more details.

When connected to a GFCI-protected supply, the Pro Hoods are suitable for use in damp locations that are protected from outside weather conditions and not subject to saturation with water and other liquids, but can be subject to moderate degrees of moisture. Refer to local codes, NEC/CEC, and or the Authority Having Jurisdiction (AHJ) for additional information.

Blower

SKU

CFM

Voltage (AC)

Blower Current

Circuit Breaker

(AMPS)

(AMPS)

 

 

 

 

 

 

 

 

 

 

Remote Blower 600 CFM

VTR630D

600

120

4.2

15

 

 

 

 

 

 

Remote Blower 1000 CFM

VTR1030D

1000

120

5.7

15

 

 

 

 

 

 

Remote Blower 1300 CFM

VTR1330E

1300

120

8.5

20* / 15**

 

 

 

 

 

 

Inline Blower 600 CFM

VTI610D

600

120

4.2

15

 

 

 

 

 

 

Inline Blower 1000 CFM

VTI1010D

1000

120

5.7

15

 

 

 

 

 

 

Integral Blower 600 CFM

VTN630C

600

120

2.7

15

 

 

 

 

 

 

Integral Blower 1000 CFM

VTN1030C

1000

120

5.4

15

 

 

 

 

 

 

* 20 Amp circuit breaker required when using the VTR1330E Remote Blower with a 27” Pro Wall Hood. ** 15 Amp circuit breaker required when using the VTR1330E Remote Blower with a 24” Pro Wall Hood.

Table 1: Blower & Circuit Breaker Ratings

English 1