Thermador 336, Range Burner Test and Adjustment, Flame Adjustment if necessary, Call Thermador if

Models: DP36 DP30 336 PRO-HARMONY Range

1 48
Download 48 pages 808 b
Page 22
Image 22
Step 9: Burner Test and Adjustment

Step 9: Burner Test and Adjustment

Flame Adjustment (if necessary):

Tube-style gas burners used in Thermador© appli- ances have air shutter systems which are similar to the illustration in Figure 15, and can be adjusted using the following method (unless adjustment is not recommended). It is necessary to remove the burner from the appliance in order to perform air- shutter adjustments.

Loosen shutter screw(s) and turn shutter to new position.

Adjust the shutter to more-closed position if the flame is lifting or blowing, or is not carrying over.

Adjust the shutter to more-open position if the flame is too yellow. (See Figure 15.)

Retighten the shutter screw(s).

After adjustment, reinstall the burner and per- form flame evaluation. The air shutter must fit over the orifice hood for proper operation of the burner.

Repeat procedure as needed until flame char- acteristics are acceptable. (See Figure 14).

FIG. 15 Air Shutter Adjustment (if necessary)

 

Air

Screw

More Open:

 

Shutter

 

Less Yellow Flame

 

 

More Closed:

 

 

Less Blue Flame

 

 

More Carryover

 

 

Less Lifting or Blowing

 

 

Flame Adjustment (if necessary): WARNING

Burner adjustments must be performed by a qualified technician. Improper adjustments may cause harmful by-products or void the appliance's warranty.

Allow burners to cool before attempting to remove them!

Call Thermador® if:

1.Any of the burners do not light.

2.Any of the burners continue to burn yellow.

19

Page 22
Image 22
Thermador 336, Range, DP30 Burner Test and Adjustment, Flame Adjustment if necessary, Air Shutter Adjustment if necessary