Step 1: Ventilation Requirements

Step 1: Ventilation Requirements

It is strongly recommended that a suitable exhaust hood be installed above the range. Downdraft ventilation should not be used. The table below indicates the Thermador hoods, by model number, that are recommended for use with all ranges.

1.Select Hood and Blower Models:

For wall installations, the hood width must, at a minimum, equal the width of the range cooking surface. Where space permits, a hood larger in width than the cooking sur- face may be desirable for im- proved ventilation perfor- mance.

For island installations, the hood width should, at a mini- mum, overhang the range cooking surface by 3" on each side.

IMPORTANT:

Ventilation hoods and blowers are designed for use with single wall ducting. However, some local building codes or inspectors may require double wall ducting. Con- sult local building codes and/or local agencies, before starting, to assure that hood and duct instal- lation will meet local requirements.

Do not install a microwave oven/ ventilator combination above the range, as these type of units do not provide the proper ventilation and are not suitable for use with the range.

2. Hood Placement:

For best smoke elimination, the lower edge of the hood should be installed 36" above the range cooking surface. (See Fig. 1).

If the hood contains any com- bustible materials (i.e. a wood covering), it must be a mini- mum of 40" above the cooking surface.

3.Consider Make-Up Air:

Due to the high volume of ven- tilation air, a source of outside replacement air is recom- mended. This is particularly important for tightly sealed and insulated homes.

A qualified heating and venti- lating contractor should be consulted.

RANGE WIDTH

WALLINSTALLATION

ISLAND INSTALLATION

 

 

 

HOOD*

BLOWER**

HOOD

BLOWER

 

 

 

PH30CS

VTR1030D,

 

 

 

 

 

PHE30 / 36

VTR1530D,

 

 

 

 

 

 

or VTN1030C

 

 

 

30" RANGE

 

 

 

HNI42YS

VTR1030D

 

 

HNW36YS

VTR1030D

 

 

 

HTNI42YS

or VTR1530D

 

 

 

 

or VTR1530D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHH30DS***

--- N/A ---

 

 

 

 

 

 

 

 

 

 

 

 

PH36CS / 42ZS

VTR1030D,

 

 

 

 

 

PHE36 / 42

VTR1530D,

 

 

 

36" RANGE

 

orVTN1030C

HNI42YS

VTR1030D

 

 

 

 

HNW36YS / 42YS

VTR1030D

HTNI42YS

or VTR1530D

 

 

 

 

 

 

 

 

 

 

 

 

or VTR1530D

 

 

 

 

 

 

 

 

 

 

 

 

PHH36DS***

--- N/A ---

 

 

 

 

 

 

 

 

 

 

Notes: * For wall installations where adequate space is available, the installer or user may elect to use a hood that is wider than the rangetop cooking surface. This may be particularly beneficial for installations having a long duct run or when heavy usage of the grill is anticipated, in which improved capturing of the cooking exhaust is desired.

** Thermador offers a choice of remote (VTR1030D or VTR1530D) or internal (VTN1030C) blowers for use in wall installations.

*** Hood models PHH30DS and PHH36DS include a 600-CFM built-in blower. For optimal ventilation, a hood model with 1000-CFM blower or greater is recommended for ranges having a griddle or grill.