ELECTRICAL SUPPLY, DUAL FUEL RANGES

Step 2: Cabinet Preparation

ELECTRICAL SUPPLY, DUAL FUEL RANGES

Installation of the range must be planned so that rough- in of junction box for the receptacle or conduit connec- tion will allow maximum clearance to the rear of the unit.

When the power supply cord or conduit is connected to the mating receptacle or junction box cover, the combined plug/receptacle or junction box cover/con- duit connector should protrude no more than 1 3/4" from the rear wall. See Figure 3B.

Refer to Figure 8 on page 14 for location of junction box on unit. To minimize binding when the unit is connected to the receptacle or junction box, orient the receptacle or conduit connector, and slide back into position.

Note: Canadian models (numbers ending in "CC") have power cord supplied with range.

FIG. 3B Wall Connection

1 3/4"

Note:

When using a 240VAC recep- tacle having its own housing, it will be necessary to recess the receptacle's housing into the rear wall. Mount the receptacle se- curely to a wall stud, then seal around the receptacle's housing. Follow all local electrical codes.

1 3/4"

Power Cord & Receptacle

Junction Box & Conduit

7

Page 10
Image 10