GAS AND ELECTRIC SUPPLY

Step 2: Cabinet Preparation

GAS AND ELECTRIC SUPPLY

FIG. 3A Gas & Electrical Supply Locations for All Dual Fuel Ranges

electrical

supply zone

8 1/2"

1 3/4" maximum protrusion

from wall for gas or electrical supply

gas

supply zone

1 3/4"

6"

6 "

6"

6"

30 1/4" (30" models)

36 1/4" (36" models)

NOTE:

If not already present, install gas shut-off valve in an easily accessible location. Make sure all users know where and how to shut off the gas supply to the range.

NOTE: The installer should inform the consumer of the location of the gas shut-off valve.

NOTE: Any opening in the wall behind the appliance and any opening in the floor under the appliance must be sealed.

The dual fuel ranges may be connected to the power supply with a range supply cord kit or by hard-wiring to the power supply. It is the responsibility of the installer to provide the proper wiring components (cord or conduit and wires) and complete the electrical connection as dictated by local codes and ordinances, and/or the National Electric Code. The units must be properly grounded. Refer to STEP 6 for details. Canadian models have power cord supplied.

The range must be connected only to the type of gas for which it is certified. If the range is to be connected to

propane gas, ensure that the propane gas supply tank is equipped with its own high pressure regulator in addition to the pressure regulator supplied with the range. (See STEP 5.)

NOTE: The range is designed for flush installation to the back wall. For a successful installation, it may be neces- sary to reposition the gas-supply line and electrical cords as the range is pushed back to its final installed position.