N.STARTUP PROCEDURES:

A.Heating System

1.Initial Startup:

: Turn off power to furnace. Before the oil piping system is placed into service, it must have been leak tested by a qualified heating contractor.

: For initial start-up of the appliance after installation, it may be necessary to purge the air out of the oil line. A qualified heating contractor should do this.

Review the following items before the initial startup. It may be helpful to review the Sequence of Operations in Section VIII of this manual, also.

a.Check all wiring for loose connections and proper hook-up. Refer to the connection diagram.

b.Leak test all field oil piping connections. Generally, this will involve pressurizing the oil piping with air while being careful to isolate the oil tank at high test pressures. A qualified heating contractor should perform this service.

c.Check to see that the vent terminal is correctly installed and the terminal openings are clear and free from blockage.

d.Make sure the air filter is in place and relatively clean of dirt and debris.

e.Make sure the thermostat is set in the heating mode of operation.

For Your Safety Read Before Operating:

: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

This appliance does not have a pilot light. It is equipped with an ignition system that automatically lights the burner. Do not attempt to light the burner by hand.

Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any oil control that has been under water.

Operating Instructions:

i.STOP! Read the safety information above.

ii.Set the thermostat to the lowest setting.

iii.Turn off all electric power to the appliance.

iv.This appliance is equipped with an ignition system that automatically lights the burner. Do not try to light the burner by hand.

v.Rotate the manual oil shutoff valve to the “ON” position.

vi.Turn on the electric power to the appliance.

vii.Set the thermostat to the desired setting.

viii.If the appliance will not operate, call your qualified service technician or oil supplier.

40

Page 43
Image 43
Thermo Products OH6FA072D48R Startup Procedures, Operating Instructions, STOP! Read the safety information above

OH6FA072D48R, OH8FA119D60B, OH6FA072DV4B, OH8FA119DV5B, OH6FX072DV4R specifications

Thermo Products has established a reputation for delivering high-quality heating solutions tailored for various applications. Among their standout offerings are the OH8FA119DV5R, OH8FA119D60R, OH6FA072D48B, OH6FA072D48N, and OH6FA072DV4N models. These units are engineered with precision and incorporate advanced technologies to deliver reliable performance in residential and commercial settings.

One of the main features of these models is their energy efficiency. They utilize modern heat exchanger designs, which allow for maximum heat transfer while minimizing energy consumption. This not only helps in reducing utility bills but also supports sustainable practices by lowering the carbon footprint. Many systems are also equipped with variable-speed motors, providing precise airflow control, which enhances comfort while operating quietly.

In addition to their energy efficiency, these units incorporate smart technology that allows for seamless integration into home automation systems. This feature enables users to monitor and control their heating systems remotely through mobile apps, making it convenient to adjust settings for optimal comfort. The smart thermostats associated with these models often feature learning capabilities, which adapt to users' habits to optimize heating schedules further.

Durability is another standout characteristic of the OH8FA and OH6FA series. Built with robust materials, these heaters are designed to withstand the rigors of daily use. Many units come with extended warranties, reflecting the manufacturer's confidence in their longevity. Furthermore, corrosion-resistant components ensure that the units maintain their performance over time, even in challenging environments.

Safety is also a key consideration in these products. Equipped with multiple safety features, including overheat protection and flame sensors, users can rest assured their heating systems operate without risk. Additionally, these models often include advanced diagnostics, making troubleshooting easier and enhancing user experience.

In summary, Thermo Products' OH8FA119DV5R, OH8FA119D60R, OH6FA072D48B, OH6FA072D48N, and OH6FA072DV4N represent a blend of efficiency, technology, durability, and safety in heating solutions. Whether for a cozy home or a large commercial space, these models offer versatile options to meet diverse heating needs while prioritizing energy conservation and user convenience. As the demand for efficient heating continues to rise, Thermo Products remains a leader in providing innovative solutions that cater to modern heating requirements.