All installations and services must be performed by qualified service personnel.
III. FURNACE SPECIFICATIONS |
| ||
MODEL |
|
|
|
HEAT INPUT RATE (BTUH) |
| 85,000 | 85,000 |
HEATING CAPACITY (BTUH) |
| 71,000 | 69,700 |
BURNER NOZZLE (GPH X |
|
|
|
ANGLE, HOLLOW CONE) |
| 0.65X80A | |
BURNER |
| #17 DMS | |
BURNER |
| #36 DMS | |
OIL PUMP PRESSURE (PSIG) |
| 100 | |
GAS SUPPLY PRESSURE (IN.W.G.) |
| ||
MINIMUM REQUIRED |
|
|
|
PROPANE |
| 11 | |
NATURAL |
| 4.5 | |
MAXIMUM ALLOWED |
|
|
|
PROPANE |
| 13.9 | |
NATURAL |
| 13.9 | |
GAS MANIFOLD PRESSURE (IN. W.G.) |
| ||
PROPANE |
| 10 + 0.3 | |
NATURAL |
| 3.5 + 0.3 | |
VENT PIPE SIZE (INCHES) | 4 |
| 4 |
DESIGN TEMPERATURE RISE (°F) 85 | 85 | ||
SEASONAL EFFICIENCY |
|
|
|
(AFUE*, %) |
| 84 | 82 |
*AFUE - INCLUDES STEADY STATE THERMAL EFFICIENCY AND OFF CYCLE LOSSES.
ELECTRICAL RATINGS AND SETTINGS: ELECTRICAL SUPPLY: 120 VAC / 60HZ / 1 PHASE
MAXIMUM TIME DELAY TYPE FUSE OR HACR BREAKER RATING: 15 AMPS
TOTAL RATED CURRENT (AMPS): 11.3 (OMC), 6.81 (GMC)
NOMINAL HEAT ANTICIPATOR SETTING
DIMENSIONS & WEIGHTS:
CABINET: WIDTH - 18 IN., DEPTH - 24 IN., HEIGHT - 57 IN.
NO.70 MOBILE HOME BASE: WIDTH - 18 5/16 IN., DEPTH - 24¼ IN., HEIGHT - 4 IN.
WARM AIR DUCT: WIDTH – 12 IN., DEPTH – 12 IN., HEIGHT - 14 ¼ IN.
COTTAGE BASE: WIDTH – 18 3/16 IN., DEPTH - 24¼ IN., HEIGHT – 14¾ IN.
FILTER QUANTITY & SIZE: (2) @ 17 ¾ IN. x 13 ¾ IN. x 1 IN. EA.
APPROXIMATE SHIPPING WEIGHT: 240 LBS.
PRODUCT LISTED UNDER UL FILE NUMBER
9