Assembly Section 2-8
ASSEMBLY
HUSCO VALVE MOUNTING
Match the holes on the valve to the holes on the valve plate. The holes on the
plate for the cables should be on your right. Always start by matching the mounting
holes on the Husco valve to the two mounting holes closest to you on the plate.
There will be two more holes on the plate to match the other mounting holes on the
valve. Use the hardware shown in the parts section to mount the valve to the valve
plate. Refer to the parts section for all parts and hardware needed.
HUSCO HYDRAULIC LINE INSTALLATION
The Tiger Husco valve used needs to access the pressure, return and power
beyond ports of the tractor. To access the ports, 1/2” adapters are used.
The pressure port is located under the drivers seat in the cab. Route the hose
from the pressure port to the high pressure filter. Next run the pressure hose from
the filter to the pressure port on the Husco valve.
The return port is located above the PTO shaft and to the right of the oil filler cap.
The return hose runs from the return port on the Husco valve to the return port on the
tractor.
The power beyond port is located by the right rear axle of the tractor. Install the
hose from the power beyond port of the Husco valve to the power beyond port of the
tractor.
RETURN PORT
PRESSURE PORT
POWER BEYOND
PORT
HIGH PRESSURE FILTER - HUSCO
The high pressure filter is mounted to the right valve mounting bracket with two
capscrews, as shown in the parts section. Attach the two adapters to the filter. The
pressure line from the tractor is plumbed to the left side of the filter. The pressure
hose that is attached to the right side of the filter feeds the pressure port of the Tiger
lift valve.