6. USING THE ALARM/REMOTE FUNCTION

6. USING THE ALARM/REMOTE FUNCTION

6.1. Alarm/Remote Input

The Alarm/Remote input terminals on the rear panel are designed to be used for both alarm and remote inputs. Select either input with the Mode Selection switch. (Refer to p. 7.)

Alarm input:

Enables spot alarm operations using such external equipment as sensors.

Remote input:

Selects the channel and position of the camera corresponding to the abbreviation number

 

when shorted to GND.

 

(Only the channel is selected for other cameras than the Combination Camera.)

1 2

3

4

G N D

5 6

7

8

G N D

9

10

11

12

 

 

 

 

G

N

D 13 14 15 16

G N D

17 18 19

20

G N D

21 22 23 24

G N D

25 26 27 28

G N D

29 30 31 32

G N D

Electrical Alarm/Remote Input Specifications Input: 32 channels, no-voltage make contact input Open Voltage: 5 VDC

Short-circuit Current: Max. 5 mA

6.2. Alarm/Remote Output