or by

COMPLEMENTARY NOTES

(1) Automatic Access to Paging

This function facilitates Paging / Paging response from a

Substation TL-600S. Just picking up the Handset of Sub-

station automatically activates Paging or Paging Response mode.

(2)Required Programming for Automatic Access to Paging from Handset Substation.

2-1) First, connect a Master Station HF-600M or TL-600M in place of a Substation TL-600S.

2-2) Program at that station a necessary function for Single Digit

Dialing such as Paging, Paging Response, Personal Number Call or etc.

2-3) Then, replace the Master Station with a Substation TL-600S.

2-4) Program "Automatic Access to Paging from Handset Substation

(Function Code 54)" at the Station No. 200 according to the

programming instructions.

(3) Single Digit Dialing and Automatic Access to Paging

By programming "Single Digit Dialing" at any master station, a

single touch of the dial activates "Station Call", "Personal Number Call", "Paging" or "Paging Response" mode. But in using a TL-600S and a HF-600S, "Automatic Access to Paging from Handset Substation" function cannot be adopted only by programming "Single Digit Dialing" at the station. It also

requires the programming for Function Code 54 at No. 200 Station.

(4)A call to Master Station from Handset or Hands-free/ Handset Substation

"Master/Sub Relationship (Function Code 61)" can be

programmed into Handset Substation TL-600S or Hands-free/

Handset Substation HF-600S etc., where you can call the relative Master Station by a single touch of the dial

picking up the Handset.

In activating a mode with Hands-free/Handset Substation HF-600S by picking up the Handset, "Privacy" switch on the Station is to be "ON" position.

(5) Call by Dialing

& Picking up the Handset

 

 

 

 

Call to Master Station

 

 

 

By dialing

By picking up

 

 

Necessary

Handset

Function

 

 

 

Programming

at

at

 

 

 

 

 

HF-620Sor

TL-600S or

 

 

 

HF-600S

HF-600S

 

 

 

 

(Privacy SW. ON)

Single Digit

 

Single Digit

 

 

 

Registration

 

 

Dialing

 

 

 

 

at Station

 

 

 

 

 

 

Master/sub

 

Programming at

 

 

Station No. 200

 

 

Relationship

 

 

 

(Function Code 61)

 

 

 

 

 

 

 

1.

Single Digit

 

 

 

 

Registration

 

 

Automatic Access to Paging

 

at Station

 

 

Paging (or Calling)

 

 

 

 

from Handset Substation

2.

Programming at

 

 

 

 

Station No.200

 

 

 

 

(Function Code 54)

 

 

Note.

Paging Call, Paging Response

or Personal Number Call

By dialing

By picking up

Handset

 

at

at

HF-620S or

TL-600S or

HF-600S

HF-600S

 

(Privacy SW. ON)

Possible

Impossible

Possible but usually Not to be used Possible across the tie-lined exchange. Impossible across the tie-lined exchange.

— 26 —

Page 27
Image 27