TOA Electronics CP-63 manual TIE-LINE Connection of the Exchanges

Models: CP-63

1 59
Download 59 pages 39.19 Kb
Page 6
Image 6

TIE-LINE CONNECTION OF THE EXCHANGES

1. Function of the Central Processing Unit CP-63

To make communications between exchanges possible in the EXES- 6000 system, the CP-63 and the Tie-line Interface Unit TI-62 are required in addition to the exchange EX-610 or the EX-620.

The TI-62 is the interface unit for transmitting and receiving audio signals and dial data signals between the exchanges.

After receiving dial signals from the station, the CP-63 transmits the dial data signals to the TI-62 and instructs it to make calls to the other exchange. The CP-63 also receives the dial data signals from the other exchange through the TI-62 and calls the station which is instructed to call by the other exchange.

Overall functions of the system using the Tie-line function are determined by programming made in the CP-63.

Exchange "A"

Exchange "B"

 

Dial

 

data

Audio

Signal

Call

Station

Station

2. Number of stations, paging zones and links

 

Maximum

 

 

 

Maximum number of stations

 

 

 

 

 

 

 

number

 

 

Maximum

 

 

 

of links

 

Number

 

 

Composition

Maximum

number

 

 

within

number of links

of

without

With Paging

of

of exchange (s)

own exchange

between tielined

exchange

Paging

(All call+7 zones)

paging

 

 

exchanges

 

 

 

 

 

 

zones

 

 

 

 

 

 

 

 

 

EX-610 EX-620

 

 

 

EX-610 EX-620

EX-610 EX-620

Without tie-lines

 

Single

 

12

16

 

 

 

 

 

 

 

Exchange

 

 

 

 

 

 

(EX-1)

 

 

 

2 exchanges

 

 

 

 

Exchange 8links

Exchange

12

16

8

*1

*1

 

"A"

 

"B"

 

(EX-2A)

 

(EX-2B)

 

 

 

3 exchanges

 

 

 

 

 

 

(EX-3A)

 

 

 

 

Exchange

 

 

 

 

 

"A"

 

 

 

 

4 links

 

4 links

12

16

4 between each

 

 

 

 

 

 

*1

*1

tielined link

 

 

Exchange

 

Exchange

 

 

 

 

"C"

4 links

"B"

 

 

 

 

 

 

 

 

(EX-3C)

 

(EX-3B)

 

 

 

*1 The links within own exchange as well as the tie-line links are used in each tie-line communication.

*2 All call paging is provided to all the paging zones of all the exchanges con- nected by tie-line.

1

All

call

56

120

48

112

+7zones

 

 

 

 

 

1

All

call

56

120

48

112

+7zones

 

 

 

 

 

2

All

call

112

240

96

224

+14zones

 

 

 

 

 

1

All

call

56

120

48

112

+7zones

 

 

 

 

 

3

All

call

168

360

144

336

+21zones

 

 

 

 

 

— 5 —

Page 6
Image 6
TOA Electronics manual TIE-LINE Connection of the Exchanges, Function of the Central Processing Unit CP-63