FUNCTIONS WHICH REQUIRE ADDITIONAL UNITS

Those functions of the CP-63 which require either the addition of specific units or processing in existing units are as mentioned below. Before installation and adjustment of equipment, make sure to check your system.

(For Data Transmitting and Receiving units, refer to Part 2. "Function Selection for Data Transmitting and Receiving units" Page 49.)

Function

Additional Equipment

Unit Model

Required

Number

 

Talk- Back from

Talk-Back Unit

TK-12

paging speaker

 

 

Conference

Conference Unit

CL-62

Remarks

Not yet available for sale.

Build this unit in all exchanges connected by tie-line. It is not possible to originate a conference from a station connected to the exchange without the CL unit but possible to participate in the conference from that station.

External PA Paging

Paging Interface Unit

PI-62

Station Paging

Paging Interface Unit

PI-62

 

Data Transmitting Unit

DT-E11

Indication and

 

 

Control

 

 

 

Data Receiving Unit

DR-B61

Tie-line System

Tie-line Interface Unit

TI-62

External PA Equipment is required.

1.Wiring of "Station Paging Assignment" located at the back of the frame of the Exchange.

2.Cutting of LM-62 jumper wire to split station paging system.

The number that can be mounted on the cabinet-mount type exchange is one (1). Use the connection cable YR-806.

When more than 2 pieces are mounted, we suggest you use rack-mount type exchange. For connection between

the exchange and the DT-E11, use the YR-802, and

the YR-803 for extension of the DT-E11 .

Such devices as indicator, control unit etc. can be made by using this unit and 24V DC power supply.

Insert this unit into a slot intended for the PI unit No. 2 (Zone No. 8-15).

— 3 —

Page 4
Image 4
TOA Electronics CP-63 manual Functions Which Require Additional Units