WIRING DIAGRAMS

Wiring diagrams are provided here for refer- ence purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment.

CAUTION: LABEL ALL WIRES PRIOR TO DIS- CONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND

GHC/GRD-5500

Robertshaw Ignition Control Equipped

1.If any of the original wire as supplied must be replaced,

1.it must be replaced with Type AWM 105° C – 18 GA. wire.

2.120V, 60Hz – Less than 3 amps.

LIMIT SW.

ON/OFF SW

120 VAC

BK

24V

LOW

VOLTAGE

BK W GND

GHC-5500

Robertshaw Ignition Control Equipped

1.If any of the original wire as supplied must be replaced,

1.it must be replaced with Type AWM 105° C – 18 GA. wire.

2.120V, 60Hz – Less than 3 amps.

LIMIT SW

ON/OFF SW WALL BLOWER SW

 

 

120 VAC

 

 

BK

BK

 

W

 

 

Appliance

24V

GND

LOW

 

Ground

VOLTAGE

BK

Screw

 

DANGEROUS APPLIANCE OPERATION.

Limit

TH TP

Switch

TP

 

 

TH

 

Thermopile

GHC Series Only

 

 

 

 

R

 

 

 

 

BK

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

BK

 

Junction Box

 

 

 

 

 

 

R

 

 

W

 

 

Transf.

 

 

 

 

 

120 V.

M

Gas Valve

 

 

 

 

 

C

P

 

GND

 

 

 

 

 

 

 

 

BL

 

 

 

24 V

BK

 

W

 

BL

 

 

 

 

 

BK

 

 

 

 

 

 

MV

TH

PV/MV

TR

GND

PV

IGN

 

 

Ignition Control

 

Green

Ground

Screw

Ignitor

Opt

 

 

 

 

 

 

Green

Blower

 

 

 

 

 

 

 

 

 

 

Ground

 

 

 

 

 

W

 

Screw

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

Junction Box

Ignitor

 

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

W

 

 

Transf.

 

 

 

 

 

 

 

120 V.

 

M

Gas Valve

 

 

 

 

 

C

 

P

 

GND

 

 

 

 

 

 

 

 

 

 

BL

 

 

 

R

24 V

 

BK

 

 

W

 

 

BL

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

MV

TH

PV/MV

TR

GND

PV

IGN

 

Ignition Control

ON/OFF Wall

Switch

WARRANTY

Your gas appliance is covered by a limited twenty year warranty. You will find a copy of the warranty accompanying this manual. Please read the warranty to be familiar with its coverage.

Factory Wired

Field Wired

Electronic System Wiring

(Without Forced Air Kit)

Normally, all parts should be ordered through your distributor or dealer. Parts will be shipped at prevailing prices at time of order.

When ordering repair parts, always give the following information:

Factory Wired

Field Wired

Electronic System Wiring

(With Forced Air Kit)

GHC/GRD-5500

(Honeywell Ignition Module Equipped)

1.If any of the original wire as supplied must be replaced,

1.it must be replaced with Type AWM 105° C – 18 GA. wire.

2.120V, 60Hz – Less than 3 amps.

LIMIT SW

ON/OFF SW

Retain this manual. File it with your other documents for future reference.

PRODUCT REFERENCE INFORMATION

We recommend that you record the following important information about your fireplace. Please contact your dealer for any questions or concerns. For the number of your nearest dealer, please call 800-731-8101

1.The model number of the appliance.

2.The serial number of the appliance.

3.The part number.

4.The description of the part.

5.The quantity required.

6.The installation date of the appliance.

If you encounter any problems or have any questions concerning the installation or appli- cation of this system, please contact your dis-

BK

R

BK

NEU. W

120 VAC. BK

24V

GND

Low Voltage

 

Green

Ground

Screw

W

BK

Ignitor

Junction Box

BK

REPLACEMENT PARTS

A complete parts list is found at the end of this manual. Use only parts supplied from the manufacturer.

tributor, or LHP directly:

LHP

1110 West Taft Avenue

Orange, CA 92865

 

 

W

Transf.

R

 

 

120 V.

Gas Valve

 

 

 

M C

P

 

 

 

 

G

 

 

 

24 V

BK

BL

W

BL

 

 

Your Fireplace's Model Number _______________________________________

Your Fireplace's Serial Number ________________________________________

The Date On Which Your Fireplace Was Installed __________________________

The Type of Gas Your Fireplace Uses ___________________________________

Your Dealer's Name _________________________________________________

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MV

 

PV/MV

 

PV

 

 

GND (Burner)

24V GND

24V

TH-W (OPT.)

SPARK

 

 

 

 

 

 

 

 

 

 

 

 

 

Ignition Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Wired

 

 

 

Field Wired

Electronic System Wiring (Without Forced Air Kit)

9

Page 9
Image 9
TOA Electronics P0055-DRG manual Warranty, Product Reference Information, Replacement Parts, West Taft Avenue Orange, CA