Note: Framing dimensions in Figures 4 - 9 are calculated for a nailing flange depth of ¹⁄₂" (13 mm).

 

Back Wall of

 

Back Wall of

 

Chase/Enclosure

 

Chase/Enclosure

Outside Wall

Including Finishing

Outside Wall

Including Finishing

Materials If Any.

Materials If Any.

 

 

INSTALLATION STEPS

Built-In Systems

WARNING: DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE FIREPLACE. AVOID ANY DRAFTS THAT ALTER BURNER FLAME PATTERNS.

15 1/2"

(394mm)

37" (940mm)

VF5000

Figure 4

Back Wall of

Chase/Enclosure

Including Finishing

Materials If Any.

41"

(1041mm)

13 1/2"

(343mm)

29"

(737mm)

37" (940mm)

58" (1473mm)

VF5000

Figure 5

19 1/2"

(495mm)

41" (1041mm)

VF6000

Figure 7

Back Wall of

Chase/Enclosure

Including Finishing

Materials If Any.

47 7/8"

(1216mm)

14 1/4"

(362mm)

33 7/8"

(860mm)

Manual background 41" (1041mm) Manual background 67 3/4" (1721mm)

VF6000

Figure 8

WARNING: DO NOT USE A BLOWER IN- SERT, HEAT EXCHANGER INSERT OR OTHER ACCESSORY NOT APPROVED FOR USE WITH THIS HEATER.

Do not burn solid fuels in this listed unvented gas room heater.

Step 1. Frame VF5000 appliance enclosures as illustrated in Figures 4, 5 and 6. Frame VF6000 appliance enclousures as illustrated in Figures 7, 8 and 9 for surround installations proceed to Step 8.

Note: The framed depth (15-1/2" for a flat wall, 29-1/4" for a corner VF5000 and 22-5/8" and 36-3/8" for a VF6000 ) must always be mea- sured from a finished surface. If a wall covering such as drywall is to be attached to the rear wall, then the dimension must be measured from the drywall surface.

Step 2. Route a 1/2" (13 mm) gas line along the left or right side framing (Figure 10 ).

6

371/4"

(946 mm)

15 1/2" (394 mm)

37" (940 mm) Manual background

Figure 6

VF5000

423/8"

(1076 mm)

19 1/2" (495 mm)

41" (1041 mm) Manual background

VF6000

Figure 9

The header may be in direct contact with the top metal spacers, but must not rest on them or be notched to fit around them.

NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

3"

VF6000 - 11"

(76 mm)

(279 mm)

 

 

 

 

VF5000 - 7 1/2"

 

 

(191 mm)

 

 

Figure 10

All appliances have a 3" long 3/8" NPT nipple installed at the valve. To quickly and easily complete the gas line routing, use the gas flex line kit, Model GFLV.

Page 6