Electrical Connection
IMPORTANT
•An electrical schematic for the toaster is provided at the back of this Manual.
•The electrical connection to the toaster requires a circuit breaker/fused disconnect. Consult appli- cable national and local code requirements to de- termine the rating of the breaker/disconnect. Elec- trical specifications are listed on the toaster’s se- rial plate and in the Specifications section of this Manual.
•The toaster’s power cord and plug provide an electrical ground connection. A separate equipotential ground connection must also be made if required by national or local codes. The location of the equipotential ground lug is shown in Figure 3.
•Consult all applicable national and local codes for further electrical connection requirements.
1.Before proceeding with the electrical connection, check that the electrical supply matches the toaster’s requirements. Refer to the serial plate and to the Specifications section of this Manual.
WARNING
ENSURE THAT BOTH THE CIRCUIT BREAKER/FUSED DISCONNECT AND THE SWITCH ARE IN THE “O” (OFF) POSITION BE- FORE PROCEEDING.
WARNING
ENSURE THAT ANY PACKING MATE- RIAL RESIDUE HAS BEEN REMOVED FROM INSIDE THE TOASTING CHAMBER.
Figure 3 - Equipotential Ground Connection
Equipotential ground
lug and symbol
2.Check that the appropriate receptacle is available for the power cord plug.
3.Insert the power cord plug into its receptacle.
4.If required by national or local codes, connect an
equipotential ground wire to the lug next to the symbol (shown in Figure 3). The equipotential
ground connection must meet all applicable na- tional and local code requirements.
Checking the Installation
1.Check that the toaster is properly connected to the electrical power supply.
2.Switch the circuit breaker/fused disconnect to the ON (“I”) position.
3.Switch the switch to the ON (“I”) position. The
display will flash as the toaster
4.Allow the toaster to
CAUTION - HOT SURFACES
USE CAUTION TO AVOID INJURY.
5.Look inside the toasting chamber and visually check that the heating elements are heating and glowing red.
6.Push and hold the key for 2 seconds.
7.Push the key.
8.Check that the digital timer begins counting down.
9.Wait for the preset time to elapse. The control should sound an alarm as follows:
•The control will beep 5 times at
•Next, the control will beep very rapidly for another 5 seconds.
•Next, the control will sound a steady tone.
10.Press the key. The timer will reset, and the steady tone will shut off.
11.Switch the switch to the OFF (“O”) position. The fan will remain in operation to allow the toaster
to cool.
12.After the fan stops, switch the circuit breaker/fused disconnect to the OFF (“O”) position.