4.0Specifications
4.2 Plus Series Specifications (w/ isolation transformer)
| MODEL NUMBER | ||
|
|
|
|
|
| CAPACITY | 600 VA (0.42 kW) |
Input |
| Input voltage | Single phase, 220 Vac, +10% to |
| Input frequency | 45 to 65 Hz | |
| Input capacity | 600VA | |
| Input power factor | Approximate unity (0.95 to 1.0) | |
|
|
| |
Battery | Battery rated voltage | 60 Vdc | |
|
|
| |
| Battery backup time when fully charged | 12 min. at full load (**) | |
| with 0.7 power factor at77° F (25° C) | 30 min. at half load (**) | |
|
|
| |
| Recharge time | Maximum 24 hrs to 100% (90% recharge after 8 hrs) (***) | |
| Type of batteries | Sealed | |
|
|
| |
Output | Output voltage | ||
|
|
| |
| Output voltage regulation | Within +/- 3%, steady state | |
|
|
| |
| Output frequency | 50/60 Hz +/- 0.5% in | |
|
|
| |
| Output voltage waveform | ||
|
|
| distortion with linear load |
| Common Mode | Less than 0.5V peak | |
| Normal Mode | Less than 10V peak | |
| Rated load power factor | 0.7 lagging (0.6 to 1.0) | |
|
|
| |
| Voltage transient characteristic | +/- 8% under 100% load step change | |
| Rated output current (rms) | 2.7A | |
|
|
| |
| Maximum output current (peak) | 8.0A | |
|
|
| |
| Inverter overload capacity | 150% for 30 seconds | |
|
|
|
|
|
| Crest factor | 3.0 |
|
|
|
|
Environment | Operating | temperature | 32 to 104° F (0 to 40° C), optimal at 77° F (25° C) |
|
|
|
|
| Storage | temperature | |
|
|
| |
| Operating humidity | 30 to 90%, no condensation | |
|
|
| |
| Altitude(****) | Less than 3000 ft (1000 m) above sea level | |
|
|
| |
| External dimensions | 8.00W x 20.38D x 10.00H in (203W x 518D x 254H mm) | |
|
|
|
|
|
| Net weight | 58.8 lb (26.7 kg) |
|
|
| |
| Acoustical noise | 50 dB at max. output, measured 3.3 ft (1 m) from front panel | |
|
|
| |
| Efficiency | 85% | |
|
|
| |
Switches | Bypass switch | Automatic bypass is provided when the run switch is in the stop | |
|
|
| position, if a fault occurs, or if an overload occurs (transfer time is |
|
|
| approximately 4 mS) |
|
|
| |
Interfaces | IBM (TM) AS/400 |
| |
| LAN Manager | See section 6.0 for details. | |
| Fault detect and input power loss |
| |
|
| RS232 ASCII |
|
|
|
| |
Options | Software for unattended |
| |
| computer shutdown | Contact Toshiba for details on this option | |
| External | battery pack | Contact Toshiba for details on this option |
|
|
|
|
(*) Output capacity reduced when input voltage is between
(**)Battery backup time may vary depending on the operating conditions including ambient temperature at the installation site.
(***) An initial charge time of 24 hrs. is necessary to obtain proper battery performance level before unit is used for battery backup.
(****) Above 3000 ft (1000 m), output capacity reduced.