4 Replacement Procedures
4-36 Minnesota 10M/10MG Series Maintenance Manual
3. Remove the FL inverter board.
Figure 4-40 Removing the FL inverter board
Installing the FL Inverter Board
To install the FL inverter board, follow the steps below and refer to the figure in the
preceding section.
1. Place the FL inverter board on the LCD module.
2. Secure one M2x3 black screw connecting the FL inverter board to the LCD display
assembly.
NOTE: If a dual inverter board is installed, you must secure it with two additional
M2.5x4 screws.
3. Connect the two connectors on either side of the board.