10
D4133738B
[Mechanical spec]
(1) External dimension 44 x 29 x 78(D) mm (Not including protrusion)
Refer to the attached external view drawing
(2) Weight Approximately 130g
(3) Lens mount C mount
(4) GND / insulation Circuit GND - Chassis electrically conducted
*
* *
* Combination of C
Combination of CCombination of C
Combination of C-
--
-mount lens
mount lensmount lens
mount lens
As for the C-mount lens used combining this camera, the projection distance from
bottom of the screw should use 8.3mm or less.
[Ambient condition]
(1)Environment condition
Performance guaranteed Temperature: From 0 through 40 °C
Humidity: From 30 through 90 % (No condensing)
Operation guaranteed Temperature: From -5 through 50 °C
Humidity: From 10 through 90 % (No condensing)
Storage Temperature: From -20 through 60 °C
Humidity: From 10 through 90 % (No condensing)
(2)EMC conditions (Electro-Magnetic Compatibility)
EMI (Electro-Magnetic Interference)
EN61000-6-4 (Examination level EN55011-A) Conformity
EMS (Electro-Magnetic Susceptibility)
EN61000-6-2 Conformity
*Conformity of EMC conditions
About the conformity of the EMC standard of this machines, it has guaranteed in the
conditions combined with the option part of 4th clause.
When used combining parts other than specification of our company, I ask you to have
final EMC conformity checked of a visitor with a machine and the whole equipment.
8.3mm or less
C-mount lens
Bottom of
the screw