[Switch setting]

(1) CCU rear-panel DIP SW

No.

Function

OFF

ON

1

 

 

 

2

E-shutter-speed

See shutter-speed table (Table 1)

3

(SHUT)

 

 

4

 

 

 

5

Shutter mode

See shutter-mode table (Table 3)

6

(SMODE)

 

 

7

Partial scan

See partial-scan table (Table 2)

8

(PART)

 

 

9

TRIG polarity

Positive

Negative

(Rising edge)

(Falling edge)

 

 

Notes: *Initial factory setting: All OFF

**Set No.9 OFF when TRIG IN OPEN.

1

SHUT 23 4

5 SMODE 6

7 PART 8

O N

(Table 1) Electronic shutter-speed

Shutter-speed

No.1

No.2

No.3

No.4

OFF

OFF

OFF

OFF

OFF

1/60s

ON

OFF

OFF

OFF

1/125s

OFF

ON

OFF

OFF

1/250s

ON

ON

OFF

OFF

1/500s

OFF

OFF

ON

OFF

1/1,000s

ON

OFF

ON

OFF

1/2,000s

OFF

ON

ON

OFF

1/5,000s

ON

ON

ON

OFF

1/10,000s

OFF

OFF

OFF

ON

1/20,000s

ON

OFF

OFF

ON

1/50,000s

OFF

ON

OFF

ON

1/100,000s

ON

ON

OFF

ON

Not acceptable

OFF

OFF

ON

ON

Not acceptable

ON

OFF

ON

ON

1/100s(FL)

OFF

ON

ON

ON

Pulse width

ON

ON

ON

ON

(Table 2) Partial-scan

Partial scan

No.7

No.8

 

 

 

OFF

OFF

OFF

1/2 partial

ON

OFF

1/4 partial

OFF

ON

Not acceptable

ON

ON

TRIG 9 0

Notes : *Don’t set Electronic shutter-speed in OFF under RTS mode.

(Table 3) Shutter-mode

 

Shutter mode

No.5

No.6

SYNC

 

Random

 

V reset

OFF

OFF

 

 

 

 

Not acceptable

ON

OFF

Internal sync

trigger

 

 

Non-reset

OFF

ON

 

 

 

 

 

Not acceptable

ON

ON

 

 

 

 

 

Non-reset

OFF

OFF

Single VD

 

 

Random

 

(Multiple shutter)

 

 

 

 

 

 

 

Ext. sync

trigger

 

Non-reset

ON

OFF

Consecutive VD

 

 

 

HD IN

 

 

V reset

OFF

ON

No VD

 

 

 

 

 

 

Restart / Reset

ON

ON

Single VD

 

 

Notes : * Under normal shutter mode partial-scan, set No.5, 6 in OFF. **Under PULSE W mode, SYNC reset is disabled.

(2)CCU rear-panel SW

Function

SW

Selected Function

Ext. SYNC IN impedance

HIGH

HIGH impedance (Initial factory setting)

(HD/VD)

 

 

75Ω

75Ω

GAIN selection (GAIN)

F

Factory-set GAIN

 

 

M

Manual GAIN adjustable via GAIN potentiometer

 

12

D4133738B

Page 18
Image 18
Toshiba CS3950D specifications Switch setting CCU rear-panel DIP SW, Set No.9 OFF when Trig in Open