9
D4133738B
(3)Restart / Reset Restart / reset available via ext. VD signal
(Switching via rear panel DIP SW, Initial OFF)
Notes : * The exposure-time (shutter-speed) is determined by ext.
VD interval.
** Enabled when rear-panel DIP SW OFF.
***Provide Consecutive HD.
[Partial scan]
(1)Operation mode
Note: Items shown as [Option] in this document is not included in your purchase as
standard components. Contact our dealer / distributor for details.
(2) Reset mode
As shown in (1) above, non-reset and V-reset is available.
([Option]: Doesn’t come as standard. Contact our dealer / distributor for details)
(a) non-reset (Electronic shutter enabled)
VD doesn’t get reset after video readout. The interval of VD signal is as follows.
*Note: Under normal shutter mode, when non-reset is selected on partial scan,
electronic shutter is valid.
Please note that the exposure time is shortened than the setting value
when the external VD is input at shorter than the above VD interval.
(b) V-reset (Electronic shutter disabled)
VD does get reset after video readout. Under internal sync, the interval of VD signal is as
follows.
Note: Items shown as [Option] in thi s document is not included in your purchase as standard
components. Contact our dealer / distributor for details.
No Scan mode Sync Reset E-shutter Normal E-shutter RTS
1
Non-reset
Enabled
[Option]
Enabled
2
V-reset
3
Consecutive HD VD IN
Non-reset
Enabled
[Option]
Enabled
4
Consecutive HD (VD) IN
V-reset
5
Non-reset
Enabled
[Option]
Enabled
6
V-reset
7
Consecutive HD VD IN
Non-reset
Enabled
[Option]
Enabled
8
Consecutive HD (VD) IN
V-reset
Internal
1/2 partial
1/4 partial
Internal
1/2 partial scan
1/4 partial scan
796H
796H
VIDEO OUT
Partial A Partial B Partial C
VD Interval
1/2 partial scan 1/4 partial scan
387H 193H
VIDEO OUT
Partial A Partial B Partial C Partial EPartial D
VD interval