(a)Non-reset mode (Under internal sync / external sync --- Consecutive VD IN) Exposure starts at the timing of TRIG signal IN. After each exposure is completed, the camera outputs video at each next VD IN timing.

Automatically returns to normal shutter if fixed H level (after approx. 1/6s)

TRIG IN not acceptable for

1V after mode chenge

TRIG IN

(Positive)

INT/EXT VD

CCD Exposure

Exposure time

(E-shutter speed or

pulse width)

VIDEO OUT

 

Definite

Outputs VD,V-SYNC

Outputs video at the next VD

during standby

timing after exposure

 

WEN OUT (Standard)

Normal shutter Random trigger shutter Normal shutter

(b) Non-reset mode (Under external sync --- Single VD IN)

After TRIG IN and exposure, the camera goes into standby until next ext. VD IN.

Automatically returns to normal shutter if fixed H level (after approx. 1/6s)

TRIG IN not acceptable for

1V after mode chenge

TRIG IN

(Positive)

EXT VD

CCD Exposure

Exposure time

(E-shutter speed or

pulse width)

VIDEO OUT

In sync with ext.VD during standby

Definite

Outputs video at the next VD

(No video output)

timing after exposure

 

WEN OUT (Standard)

Normal shutter Random trigger shutter Normal shutter

*Don’t provide ext. VD IN during exposure. ** After automatic return, fix ext. VD IN at Hi.

(c)V-reset mode (Under internal sync / external sync --- No VD IN)

Exposure starts at the timing of TRIG signal IN. After each exposure is completed, the camera outputs video immediately by resetting VD. (HD is not reset)

3

D4133738B

Page 9
Image 9
Toshiba CS3950D specifications Trig