Troubleshooting

CAUTION

Use Caution Not to Damage Connectors when making Voltage Measurements or Jumping Terminals

From previous page

Does damper blade move to the full

open position?

Y

Is there pilot flame?

Y

Does Main Burner operate?

Y

 

Error code #55 on display.

 

 

 

N

Remove damper from heater and

 

Does water heater begin to

 

jump black & yellow wires of

 

 

 

operate?

 

heater harness. Refer to photo on

 

 

 

 

 

 

this page.

 

 

Y

 

 

 

 

 

 

 

N

Error code #62 on display. See

 

Check for debris limiting damper

 

 

 

“Pilot Will Not Light”.

 

rotation. If no debris, replace

 

 

 

damper.

N

Error code #62 on display. See

 

 

 

 

 

 

 

 

“Pilot Lights, No Flame Signal”

 

 

 

Does burner continue until

thermostat set point is reached?

See setting display in Service Mode

and displaying temperature

sensors.

Y

Does the flue damper rotate to the

fully closed position?

Y

System okay

N

Error code #63 on display. See

 

 

“Main Burner Short Cycles”.

N

Error code #56 on display.

Check for debris limiting damper

 

 

rotation. If no debris, replace

 

damper

Damper vane show in open position. If damper

is closed, disconnect from harness and REMOVE damper from water heater.

6

Harness shown disconnected from damper with BLACK and YELLOW wires jumped.

Error Code Shown

in Water Heater Display

Status Service Needed

SELECT Lockout RESET

Example of error code shown on control display.

Page 8

8

Page 8
Image 8
Bradford-White Corp D-38T-155 service manual From previous, Operate?, Pilot Will Not Light, Displaying temperature Sensors