| SERVICE PROCEDURE | |
|
|
|
|
|
|
| Pilot Inspection | |
|
|
|
|
|
| |||
| Condition: |
|
|
|
|
| ||
Error code 57: Flame Rod Shorted |
|
|
|
| ||||
| to Ground |
|
|
|
| |||
|
|
|
|
|
| |||
|
|
|
|
|
|
| ||
Disconnect power. Shut off gas | Check to see if pilot shield is touching |
|
|
| ||||
supply to water heater. Slide out | pilot flame sensor or flame sensor |
| Check pilot flame sense wire for | |||||
burner assembly (see section on |
| touching pilot hood. Bend shield to |
| broken insulation. Replace pilot if | ||||
|
| |||||||
“removing pilot and main burner | prevent interference or replace pilot |
| defective | |||||
assembly”). | shield. |
|
|
| ||||
| Make sure pilot shield |
|
|
|
| |||
|
|
|
|
| ||||
|
|
|
|
| ||||
| clears flame sense rod |
|
|
|
| |||
|
|
|
|
|
|
| Reinstall pilot and burner assembly. | |
Flame Sense Rod |
|
| Reconnect gas line union, turn on | |||||
|
| gas. | ||||||
|
|
|
| |||||
|
|
|
|
| ||||
Spark Electrode |
|
| Check for Gas Leaks | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Reconnect power and verify proper | |
|
|
|
|
|
|
| ignitions. |
Page 28
28