[Procedure 2]
Is the connector J6 on the finisher controller PC board, J114 of the height sensor (PS1) or relay
connector J212 disconnected?
YES Connect the connector.
NO
Is the voltage between J6-2(+) and J6-4(-) on the finisher controller PC board 5V DC?
NO Replace the finisher controller PC board.
YES
Is the wiring between the finisher controller PC board and height sensor correct?
NO Correct the wiring.
YES
Replace the height sensor.
[Procedure 3]
Is the problem solved by readjusting the DIP switch?
YES End
NO
Is the wiring between the finisher controller PC board and height sensor (PS1) correct?
NO Correct the wiring.
YES
Is the voltage between J6-2(+) and J6-4(-) on the finisher controller PC board 5V DC?
NO Replace the finisher controller PC board.
YES
Replace the height sensor.