FC-210/310 PREVENTIVE MAINTENANCE 3- 4 February 2002 © TOSHIBA TEC
31.Cleaning roller 40/60 ch.3.6.7
<P28-I45>
32.Upper thermistors A (40/60) Fuser unit
Fuser unit 33.Lower thermistors A (40/60) counter
34.Fuser inlet guide A (40/60) (08-854)
35.Fuser exit guide A (40/60)
36.Paper exit roller A
Image quality
37.Image quality sensor’s area (40/60) *11
control Drum K
Color 38.Color registration sensor (40/60) life counter
registration (08-843)
Laser unit 39.Slit glass (40/60)
40.Pick-up roller A (40/60) 90 <P14-I13>
41.Feed roller A (40/60)
42.Separation roller A (40/60)
43.Bypass pick-up roller A (40/60) 90 <P17-I52>
Paper feeding
44.Bypass feed roller A (40/60)
system 45.Bypass separation roller A (40/60)
46.Registration roller A (40/60)
47.Paper guide (40/60)
48.Paper dust removal brush (40/60)
49.Drive gears (tooth face) W
50. Registration unit support bushings W
51.Original glass
or A (40/60)
52.Platen cover
or A (40/60)
53.Mirror-1 (40/60)
54.Mirror-2 (40/60)
55.Mirror-3 (40/60)
Scanner 56. Reflector (40/60)
57.Lens (40/60)
58.Exposure lamp
59.Original-width indicator
60.Automatic original detection unit
61.Slide sheet
62.Air filter (40/60)
63.Transfer belt 120/120 <P30-I2>
Transfer/ 64. Transfer roller (Y, M, C, K) 120/120 <P30-I22>
transport 65. Drive roller cleaning felt 120/120 <P30-I27> Transfer belt
unit 66. Transfer belt cleaning blade 120/120 <P30-I46> unit counter
(TBU) 67. Transfer belt recovery blade (120/120) (08-853)
68.Transfer belt drive roller (120/120)
69.Transfer belt driven roller (120/120)
Cleaning Lubri- Replace- Opera- Remarks Reference
Section Item to inspect (X 1000) cation ment tion <P-I> counter
(X 1000) check