3 Tests and Diagnostics  3.29  SETUP 
3-100   [CONFIDENTIAL]    PORTEGE R200 Maintenance Manual (960-519) 
or BackSpace. Press ↓ to move the cursor to the right and ↑ to move the 
cursor to the left when you set the date and time. 
For the Alarm Time, set the time to turn on the power automatically. The 
“second” cannot be set. When it is set to “Disabled”, the time to turn on 
automatically is not set. 
For the Alarm Date Option, set the date to turn on the power automatically. 
When it is set to “Disabled”, the time to turn on automatically is not set. 
The Wake-up on LAN is a function to turn on the power automatically by the 
call from the administrator. It can be set to “Enabled” only when “Built-in 
LAN” is set to “Enabled”. To activate this function, use the AC adapter. 
NOTE:  1.  Do not remove the AC adaptor and battery pack at the same time when you 
        use this feature.  If you do so, data saved by the resume function will be lost.  
        You must also reset this option. 
2.  If you have set a password and the computer boots by the Auto Power On  
        function and Resume is on, the computer will start with the instant security 
    function enabled. The password = message is not displayed; however, you  
        must enter the password to use the computer. 
3.  This option is enabled only once, the setting is reset, after booting up. 
(d) Diagnostic Mode 
This option enables/disables the HW Diagnostic test function. 
Disabled      Disables the HW Diagnostic test function. (Default) 
Enabled      Enables the HW Diagnostic test function. 
9. Configuration 
This option displays the configuration method. 
(a) Device Config. 
The devices are initialized when the PNP OS loads. 
Setup by OS  Operating system sets devices that it can control. 
(Default) 
All Devices  BIOS sets all devices. 
NOTE: When using installed OS, selecting “Set by OS” is recommended. But, when 
executing a diagnostic program, select “ All Devices”.