Toshiba RAV-SM1402CT-E, SP562AT-E Parts Name Of Remote Controller, Display section, 10 11 12

Models: RAV-SM562AT-E RAV-SM562CT-E RAV-SM802AT-E RAV-SM802CT-E RAV-SM1402CT-E RAV-SM1402AT-E RAV-SM1102AT-E SP1402AT-E RAV-SM1102CT-E SP802AT-E SP1102AT-E SP562AT-E

1 18
Download 18 pages 35.13 Kb
Page 7
Image 7
PARTS NAME OF REMOTE CONTROLLER

PARTS NAME OF REMOTE CONTROLLER

Display section

In the display example, all indicators are displayed for the explana- tion.

In reality only, the selected contents are indicated.

When turning on the leak breaker at the first time, [SET DATA] flashes on the display part of the remote controller. While this display is flashing, the model is being automatically confirmed. Accordingly, wait for a while after [SET DATA] display has disappeared, and then use the remote controller.

 

 

 

CODE No.

SET DATA SETTING TEST

 

 

 

UNIT No.

 

H

R.C.

No.

 

 

 

 

TEMP.

 

 

ON / OFF

 

TIMER SET

FAN

MODE

 

TIME

SWING/FIX

VENT

FILTER

 

 

 

RESET TEST

SET CL

UNIT

 

Display section

Operation section

 

 

7 8

 

 

1

2

 

 

 

3

 

 

 

4

SET DATA SETTING TEST

 

 

 

UNIT No.

5

H

R.C.

No.

 

 

 

6

 

 

 

 

 

 

 

14

9

CODE No.

10

11

12

13

1 SET DATA display

Displayed during setup of the timer.

2 Operation mode select display

The selected operation mode is displayed.

3 CHECK display

Displayed while the protective device works or a trouble occurs.

4 Timer time display

Time of the timer is displayed.

(When a trouble occurs, the check code is dis- played.)

5 Timer SETIN setup display

When pushing the Timer SETIN button, the display of the timer is selected in order of [OFF]

[OFF] repeat OFF timer [ON]

No display.

6 Filter display

If “FILTER Display section ” is displayed, clean the air filter.

7 TEST run display Displayed during a test run.

8 Flap position display

Displays flap position.

9 SWING display

Displayed during up/down movement of the flap.

10 Set up temperature display

The selected set up temp. is displayed.

11 Remote controller sensor display

Displayed while the sensor of the remote controller is used.

12 PRE-HEAT display

Displayed when the heating operation starts or defrost operation is carried out.

While this indication is displayed, the indoor fan stops or the mode enters in LOW.

13 No function display

Displayed if there is no function even if the button is pushed.

14 Air volume select display

The selected air volume mode is dis- played.

(AUTO) (HIGH) (MED.)

(LOW)

4

Page 7
Image 7
Toshiba RAV-SM1402CT-E, SP562AT-E, SP1102AT-E, SP802AT-E Parts Name Of Remote Controller, Display section, 10 11 12