5.3.Standby mode
Figure 8 shows the standby sequence.
During access
ldle (Max.24X)
ldle (4.4 - 10X)
Read or Seek |
|
|
command | 8 s | 24 s |
Figure 8 Standby Sequence
Rotational speed move onto 4.4 to 10X mode in 8 seconds of the Read or Seek command. After 24 seconds (default value), it move onto standby mode. (a stop spindle motor)
6. Interface
(1)The interface is based on
1.0and
(Small Form Factor Committee Specification of
(2)48 types of commands are usable including ATA & ATAPI Commands.
(3)The 128 KByte data buffer handles both high speed and low speed data transmission.
(4)The largest one block size on playback is 2,448 Bytes. The data length for each block is changeable by command.
(5)Please refer to the standard of
6.1.I/O cable
Table 1 shows the cable parameters.
| Min | Max |
Cable length |
| 0.46 m |
Driver IoL sink current for 5V operation | 12 mA |
|
Driver IoH source current |
| |
|
|
|
Cable capacitive loading |
| 200 pF |
Power Supply cablesPIN No.38 - 42(+B),43 - 45(GND) | 1.5 A |
|
Table 1 Cable parameters
6.2.Signal summary
The physical interface consists of single ended TTL compatible receivers and drivers communicating through a
13/27 |
|