Name:Enter a name for Port Triggering entries. Up to 28 characters can be entered.

Interface:Select an interface for forwarding data packets.

Trigger Port: Enter the trigger port number or the range of port. Only when the trigger port initiates connection will all the corresponding incoming ports open and provide service for the applications, otherwise the incoming ports will not open.

Trigger Protocol: Select the protocol used for trigger port.

Incoming Port: Enter the incoming port number or range of port numbers. The incoming port will open for follow-up connection after the trigger port initiates connection.

Incoming Protocol: Select the protocol used for incoming port.

Status:

Activate or inactivate the entry.

Manual background Note:

The Trigger Port and Incoming Port should be set in the range of 1-65535. The Incoming Port can be set in a continuous range such as 8690-8696.

The Router supports up to 16 Port Triggering entries. Each entry supports at most 5 groups of trigger ports and overlapping between the ports is not allowed.

Each entry supports at most 5 groups of incoming ports and the sum of incoming ports you set for each entry should not be more than 100.

List of Rules

In this table, you can view the information of the entries and edit them by the Action buttons.

The first entry in Figure 3-33indicates that: This is a Port Triggering entry named host1, When the LAN host initiates a TCP request via port of 5354, the incoming port 5355 of WAN1 will open for TCP and UDP protocol. This entry is activated.