TP-Link TL-SF1016DS, TL-SF1048, TL-SF1024D manual Site Requirements, Temperature/Humidity, Clearness

Models: TL-SF1016DS TL-SF1016 TL-SF1024 TL-SF1024D TL-SF1048

1 24
Download 24 pages 20.23 Kb
Page 9
Image 9
■■ Site Requirements

10/100Mbps Fast Ethernet Switch

Site Requirements

Temperature/Humidity





Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device. For normal temperature and humidity of the device, please check the following table.

Environment

Temperature

Humidity

 

 

 

Operating

0~ 40

10% ~ 90%RH Non-condensing

 

 

 

Storage

-40~ 70

5% ~ 90%RH Non-condensing

 

 

 

Clearness

The dust accumulated on the device can be absorbed by static electricity and result in poor contact of metal contact points. Some measures have been taken for the device to prevent static electricity, but too strong static electricity can cause deadly damage to the electronic elements on the internal circuit board. To avoid the effect of static electricity on the operation of the device, please attach much importance to the following items:

Dust the device regularly, and keep the indoor air clean.

Keep the device well grounded and ensure static electricity has been transferred.

Electromagnetic Interference

Electronic elements including capacitance and inductance on the device can be affected by external interferences, such as conducted emission by capacitance coupling, inductance coupling, and impedance coupling. To decrease the interferences, please make sure to take the following measures:

Use the power supply that can effectively filter interference from the power grid.

Keep the device far from high-frequency, strong-current devices, such as radio transmitting station.

Use electromagnetic shielding when necessary.