10 CONFIGURATION

The operative configuration of the unit can be changed using the below indicated procedure.

Switch the instrument -Off-

Keep the <ENTER> key pressed and press the <Trigger> push button until the instrument displays the indication relevant with the technical unit selection.

10.1Technical Unit selection

the display will indicate one of the following technical units (Celsius, Fahrenheit and Kelvin):

Set

Lock

e

Set

Lock

e

Set

Lock

e

Press the <▲> or <▼> key if you require to select a new technical unit

Press the <SEL> key to select the new configuration step or press the <Trigger> to switch the instrument -Off-. The new selection will be automatically memory stored.

10.2Thermocouple input enabled

Press the <SEL> key until the following indication is displayed :

Set

°C

Lock

e

or

Set

°C

Lock

e

Press the <▲> or <▼> key to enable (or to disable) the thermocouple auxiliary input operation.

Press the <SEL> key to select the new configuration step or press the <Trigger> to switch the instrument -Off-. The new selection will be automatically memory stored.

10.3Temperature Scale selection

Press the <SEL> key until one of the following indication is displayed :

Set

°C

Lock

e

or

Set

°C

Lock

e

Press the <▲> or <▼> key to select the required International Temperature Scale.