DATA4 'X' (ASCII CODE)

$0C - Last 4 chars tag description --------------------------------------------------

RX

DATA1

'X' (ASCII CODE)

 

DATA2

'X' (ASCII CODE)

 

DATA3

'X' (ASCII CODE)

 

DATA4

-

 

$0D - Alarm status ------------------------------------------------------------------------

RX

DATA1

LAL Status (0=No alarm - 1=Alarm active)

 

DATA1

HAL Status (0=No alarm - 1=Alarm active)

 

DATA1

-

 

DATA1

-

 

$1C - Firmware version -----------------------------------------------------------------

RX

DATA1

'X' (ASCII CODE)

 

DATA2

'X' (ASCII CODE)

 

DATA3

'X' (ASCII CODE)

 

DATA4

'X' (ASCII CODE)

 

15.3.2Computer data setting from PC to OSP

Computer

 

OSP

 

Tx IDNAME

Rx IDNAME

Proceed if the name is acknowledged

Rx IDNAME

Tx IDNAME

If not, do not answer

Tx Instruction

Rx Instruction

 

Rx Instruction

Tx Instruction

 

Tx DATA 1

Rx DATA 1

 

Rx char

Tx char

 

Tx DATA 2

Rx DATA 2

 

Rx char

Tx char

 

Tx DATA 3

Rx DATA 3

 

Rx char

Tx char

 

Tx DATA 4

Rx DATA 4

 

Rx char

Tx char

 

Tx CHKSUM

Rx char

 

Rx char

Tx char

 

IDNAME, Instruction, DATA 1, DATA 2, DATA 3, DATA 4 and CHKSUM are 8-bit values (1 byte). CHKSUM = DATA 1+DATA 2+DATA 3+DATA 4 .AND. FF

The above is useful to verify correct received data.

The minimum time-out of OSP is 3 seconds.

IDNAME is set to 1.

Writing values

$80 - Emissivity----------------------------------------------------------------------------

TX

DATA1

0

 

DATA2

0

 

DATA3

0

 

DATA4

VALUE

 

VALUE = EMISSIVITY X 100

 

$82 - Tc type --------------------------------------------------------------------------------

TX

DATA1

0

 

DATA2

Tc type (0=Tc K - 1=Tc S)

 

DATA3

0

 

DATA4

0

 

$84 - HAL Setpoint------------------------------------------------------------------------

TX

DATA1

VALUE (HH)

 

DATA2

VALUE (H)

 

DATA3

VALUE (L)

 

49

Page 49
Image 49
Omega OSP SERIES manual Computer data setting from PC to OSP, Writing values