Threshold: Specify the threshold for the selected link event.
For Symbol Period Error, it is the number of error symbols in
the period that is required to be exceeded.
For Frame Error, it is the number of error frames in the period
(measured by 100ms) that is required to be exceeded.
For Frame Period Error, it is the number of error frames in the
period (measured by frames) that is required to be exceeded.
For Frame Seconds Error, it is the number of error frame
seconds in the period that is required to be exceeded.
Window: Specify the detection period.
For Frame Period Error, the period is specified by a number of
received frames.
For other link events, the period is specified by a time interval.
Notify: Choose whether to notify the selected link event or not.
8.3 RFI
On this page, you can choose whether to notify the link faults like dying gasp and critical event.
Choose the menu Ethernet OAMRFIRemote Failure Indication to load the following page.
Figure 8-7 Remote Failure Indication
The following entries are displayed on this screen:
Remote Failure Indication Config
Port Select: Click the Select button to quick-select the corresponding port
based on the port number you entered.
121