Model
Number
Description
YC | D | 480 | A | 4 |
| H |
| A | 1 |
| A |
| 4 |
| F |
| D | 1 | A | 0 | 0 | 0 |
| 0 |
| 0 | 0 |
| 0 |
| 0 | 0 | 0 |
| 0 |
| 05 | ||||
12 | 3 | 456 | 7 |
| 8 |
| 9 |
| 10 |
| 11 |
| 12 | 13 |
| 14 |
| 15 |
| 16 | 17 | 18 | 19 | 20 |
| 21 |
| 22 |
| 23 | 24 | 25 | 26 | 27 |
| 28 |
| 29 |
Digit 1, 2 — Unit Function
TC | = | DX Cooling, No Heat |
TE | = | DX Cooling, Electric Heat |
YC | = | DX Cooling, Natural Gas Heat |
Digit 3 — Unit Airflow Design
D= Downflow Configuration H = Horizontal Configuration
Digit 4, 5, 6 — Nominal Cooling Capacity
330 = 27½ Tons
360 = 30 Tons
420 = 35 Tons
480 = 40 Tons
600 = 50 Tons
Digit 7 — Major Development Sequence
A = First
Digit 8 — Power Supply (See Note 1)
E = 208/60/3 F = 230/60/3 4 = 460/60/3 5 = 575/60/3
Digit 9 — Heating Capacity (See Note 4)
0= No Heat (TC only) L = Low Heat (YC only) H = High Heat (YC only)
Note: When second digit is “E” for Electric Heat, the following values apply in the ninth digit.
A = 36 KW B = 54 KW C = 72 KW D = 90 KW E = 108 KW
Digit 13 — Supply Fan Motor, HP
1 = 7.5 Hp Std. Eff.
2 = 10 Hp Std. Eff.
3 = 15 Hp Std. Eff.
4 = 20 Hp Std. Eff.
5 = 7.5 Hp Hi. Eff.
6 = 10 Hp Hi. Eff.
7 = 15 Hp Hi. Eff.
8 = 20 Hp Hi. Eff.
Digit 14 — Supply Air Fan Drive Selections (See Note 3)
A = 550 RPM | H = 500 RPM |
B = 600 RPM | J = 525 RPM |
C = 650 RPM | K = 575 RPM |
D = 700 RPM | L = 625 RPM |
E = 750 RPM | M = 675 RPM |
F = 790 RPM | N = 725 RPM |
G = 800 RPM |
|
Digit 15 — Fresh Air Selection
A= No Fresh Air
B=
C=
D=
E=
F= “C” Option and Low Leak Fresh
Air Damper
G= “D” Option and Low Leak Fresh Air Damper
H= “E” Option and Low Leak Fresh Air Damper
Digit 16 — System Control
1 = Constant Volume
2 = VAV Supply Air Temperature Control w/o Inlet Guide Vanes
3 = VAV Supply Air Temperature Control w/Inlet Guide Vanes
4 = VAV Supply Air Temperature Control w/Variable Frequency Drive w/o Bypass
5 = VAV Supply Air Temperature Control w/Variable Frequency Drive and Bypass
Note: Zone sensors are not included with option and must be ordered as a separate accessory.
Digit 17 - 29 — Miscellaneous
A= Service Valves (See Note 2)
B= Through the Base Electrical Provision
C=
D=
External Handle
E=
F= ICS Control Option — Trane Communication Interface, Supply Air Sensing and Clogged Filter Switch
G= Ventilation Override
H= Hinged Service Access
J= Condenser Coil Guards
K= LonTalk Communication Interface
L= Special
M= Stainless Steel Drain Pans
N= Black Epoxy Coated Condenser Coil
Digit 10 Design Sequence
A = First
Digit 11 — Exhaust
0 = None
1 = Barometric Relief (Available w/Economizer only) 2 = Power Exhaust Fan (Available w/Economizer only)
Digit 12 — Filter
A = Standard 2” Throwaway Filters
B = High Efficiency 2” Throwaway Filters C = High Efficiency 4” Throwaway Filters
Note:
1.All voltages are across the line starting only.
2.Option includes Liquid, Discharge, Suction Valves.
3.Supply air fan drives A thru G are used with
4.Electric Heat KW ratings are based upon voltage ratings of 240/480/600 V. Voltage offerings are as follows (see table
|
|
|
| KW |
|
|
Tons | Voltage | 36 | 54 | 72 | 90 | 108 |
27½ to 35 | 240 | x | x |
|
|
|
| 480 | x | x | x | x |
|
| 600 |
| x | x | x |
|
40 and 50 | 240 |
| x |
|
|
|
| 480 |
| x | x | x | x |
| 600 |
| x | x | x | x |
5. The service digit for each model number contains 29 digits; all 29 digits must be referenced.
14 |