Image 17

Performance Data

10 Tons Gross Cooling Capacities and Capacity Curves

Table 8.

Gross Cooling Capacities (MBh) 10 Tons TWA120A Heat Pump Only

 

 

 

 

 

 

Suction Temperature (°F)

 

 

Outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp (°F)

30

35

40

45

50

55

 

 

 

 

 

 

 

 

 

Head press PSIG

167

172

178

183

189

195

65

Cap. Btuh/1000

110.6

121.1

132.1

143.7

155.9

168.6

 

Unit kW

7.87

8.04

8.22

8.41

8.61

8.83

 

 

 

 

 

 

 

 

 

Head press PSIG

192

197

202

208

214

221

75

Cap. Btuh/1000

105.4

115.4

126.1

137.3

149.1

161.4

 

Unit kW

8.56

8.75

8.95

9.16

9.38

9.62

 

 

 

 

 

 

 

 

 

Head press PSIG

219

224

230

236

243

250

85

Cap. Btuh/1000

100

109.6

119.9

130.7

142

153.9

 

Unit kW

9.38

9.59

9.82

10.05

10.3

10.55

 

 

 

 

 

 

 

 

 

Head press PSIG

248

254

260

267

274

281

95

Cap. Btuh/1000

94.5

103.7

113.5

123.8

134.7

146.1

 

Unit kW

 

10.35

10.58

10.82

11.07

11.59

 

 

 

 

 

 

 

 

 

Head press PSIG

281

287

293

300

307

315

105

Cap. Btuh/1000

88.8

97.6

107

116.8

127.1

137.8

 

Unit kW

11.45

11.7

11.96

12.22

12.48

12.74

 

 

 

 

 

 

 

 

 

Head press PSIG

316

322

329

336

343

351

115

Cap. Btuh/1000

83.1

91.4

100.3

109.6

119.2

129.2

 

Unit kW

12.69

12.95

13.21

13.48

13.73

13.98

Notes:

1.Performance data calculated at 15°F subcooling and 20°F superheat and does not include capacity loss due to refrigerant lines.

Figure 9. Capacity Curves 10 Tons TWA120A Heat Pump Only

SSP-PRC001-EN