Transcend Information TS16G-64GCF400 Transcend Information Inc, TS16G~64GCF400, Flush Cache - E7h

Models: 400X

1 88
Download 88 pages 37.44 Kb
Page 62
Image 62
￿Erase Sector(s) - C0h

TS16G~64GCF400

400X CompactFlash Card

 

 

 

￿Erase Sector(s) - C0h

This command is used to pre-erase and condition data sectors in advance of a Write without Erase or Write Multiple without Erase command. There is no data transfer associated with this command but a Write Fault error status can occur.

Bit ->

7

6

5

 

4

 

3

 

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

Command (7)

 

 

 

 

 

C0h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C/D/H (6)

1

LBA

1

 

Drive

 

 

 

Head (LBA 27-24)

 

 

 

 

 

 

 

 

 

 

Cyl High (5)

 

 

 

Cylinder High (LBA 23-16)

 

 

 

 

 

 

 

 

 

 

Cyl Low (4)

 

 

 

Cylinder Low (LBA 15-8)

 

 

 

 

 

 

 

 

 

 

Sec Num (3)

 

 

 

Sector Number (LBA 7-0)

 

 

 

 

 

 

 

 

 

 

 

Sec Cnt (2)

 

 

 

 

Sector Count

 

 

 

 

 

 

 

 

 

 

 

 

 

Feature (1)

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿Flush Cache – E7h

This command causes the card to complete writing data from its cache. The card returns status with RDY=1 and DSC=1 after the data in the write cache buffer is written to the media. If the Compact Flash Storage Card does not support the Flush Cache command, the Compact Flash Storage Card shall return command aborted.

Bit ->

7

6

5

4

 

3

2

 

1

0

 

 

 

 

 

 

 

 

 

 

 

Command (7)

 

 

 

 

E7h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C/D/H (6)

 

X

 

Drive

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Cyl High (5)

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cyl Low (4)

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sec Num (3)

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sec Cnt (2)

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Feature (1)

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿Format Track - 50h

This command writes the desired head and cylinder of the selected drive with a vendor unique data pattern (typically FFh or 00h). To remain host backward compatible, the CompactFlash Storage Card expects a sector buffer of data from the host to follow the command with the same protocol as the Write Sector(s) command although the information in the buffer is not used by the CompactFlash Storage Card. If LBA=1 then the number of sectors to format is taken from the Sec Cnt register (0=256). The use of this command is not recommended.

 

Bit ->

 

7

6

5

 

4

 

3

 

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command (7)

 

 

 

 

 

 

50h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C/D/H (6)

 

1

LBA

1

 

Drive

 

 

 

Head (LBA 27-24)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cyl High (5)

 

 

 

 

Cylinder High (LBA 23-16)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cyl Low (4)

 

 

 

 

Cylinder Low (LBA 15-8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sec Num (3)

 

 

 

 

 

X (LBA 7-0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sec Cnt (2)

 

 

 

 

Count (LBA mode only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Feature (1)

 

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transcend Information Inc.

 

 

 

62

 

 

 

 

 

 

 

V1.0

Page 62
Image 62
Transcend Information TS16G-64GCF400 Transcend Information Inc, TS16G~64GCF400, 400X CompactFlash Card, Flush Cache - E7h