TS16G~64GCF400 |
| 400X CompactFlash Card |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Word | Default |
| Total | Data Field Type Information |
|
|
|
| Address | Value |
| Bytes |
| |
|
|
|
|
|
| |||
| 51 | 0200h |
| 2 | PIO data transfer cycle timing mode |
| ||
|
|
|
|
|
|
|
| |
| 52 | 0000h |
| 2 | Obsolete |
| ||
|
|
|
|
|
|
|
| |
| 53 | 000Xh |
| 2 | Field Validity |
| ||
|
|
|
|
|
|
|
| |
| 54 | XXXXh |
| 2 | Current numbers of cylinders |
| ||
|
|
|
|
|
|
|
| |
| 55 | XXXXh |
| 2 | Current numbers of heads |
| ||
|
|
|
|
|
|
|
| |
| 56 | XXXXh |
| 2 | Current sectors per track |
| ||
|
|
|
|
|
|
|
| |
| XXXXh |
| 4 | Current capacity in sectors (LBAs)(Word 57 = LSW, Word 58 = MSW) |
| |||
|
|
|
|
|
|
|
| |
| 59 | 01XXh |
| 2 | Multiple sector setting |
| ||
|
|
|
|
|
|
|
| |
| XXXXh |
| 4 | Total number of sectors addressable in LBA Mode |
| |||
|
|
|
|
|
|
|
| |
| 62 | 0000h |
| 2 | Reserved |
| ||
|
|
|
|
|
|
|
| |
| 63 | 0007h |
| 2 | Multiword DMA transfer. In PC Card modes this value shall be 0h |
| ||
|
|
|
|
|
|
|
| |
| 64 | 0003h |
| 2 | Advanced PIO modes supported |
| ||
|
|
|
|
|
|
|
|
|
|
| 65 | 0078h |
| 2 | Minimum Multiword DMA transfer cycle time per word. In PC Card modes this value |
| |
|
| shall be 0h |
| |||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| 66 | 0078h |
| 2 | Recommended Multiword DMA transfer cycle time. In PC Card modes this |
| |
|
| value shall be 0h |
| |||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
| 67 | 0078h |
| 2 | Minimum PIO transfer cycle time without flow control |
| ||
|
|
|
|
|
|
|
| |
| 68 | 0078h |
| 2 | Minimum PIO transfer cycle time with IORDY flow control |
| ||
|
|
|
|
|
|
|
| |
| 0000h |
| 20 | Reserved |
| |||
|
|
|
|
|
|
|
| |
| 80 | 0000h |
| 2 | Major version number |
| ||
|
|
|
|
|
|
|
| |
| 81 | 0000h |
| 2 | Minor version number |
| ||
|
|
|
|
|
|
|
| |
| 82 | 7028h |
| 2 | Command sets supported |
| ||
|
|
|
|
|
|
|
| |
| 83 | 500Ch |
| 2 | Command sets supported |
| ||
|
|
|
|
|
|
|
| |
| 84 | 4000h |
| 2 | Command sets supported |
| ||
|
|
|
|
|
|
|
| |
| 85 | XXXXh |
| 2 | Command sets enabled |
| ||
|
|
|
|
|
|
|
| |
| 86 | XXXXh |
| 2 | Command sets enabled |
| ||
|
|
|
|
|
|
|
| |
| 87 | XXXXh |
| 2 | Command sets enabled |
| ||
|
|
|
|
|
|
|
| |
| 88 | 007Fh |
| 2 | Ultra DMA Mode Supported and Selected |
| ||
|
|
|
|
|
|
|
| |
| 89 | XXXXh |
| 2 | Time required for Security erase unit completion |
| ||
|
|
|
|
|
|
|
| |
| 90 | XXXXh |
| 2 | Time required for Enhanced security erase unit completion |
| ||
|
|
|
|
|
|
|
| |
|
| 91 | XXXXh |
| 2 | Current Advanced power management value |
| |
| 92 | XXXXh |
| 2 | Master password revision code |
| ||
|
|
|
|
|
|
| ||
| 0000h |
| 70 | Reserved |
| |||
|
|
|
|
|
|
| ||
| 128 | XXXXh |
| 2 | Security status |
| ||
|
|
|
|
|
|
| ||
| 0000h |
| 64 | Vendor unique bytes |
| |||
|
|
|
|
|
|
| ||
| 160 | 81F4h |
| 2 | Power requirement description |
| ||
|
|
|
|
|
|
| ||
| 161 | 0000h |
| 2 | Reserved |
| ||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
Transcend Information Inc. |
| 64 |
|
V1.0