￿SMART Data Structure

 

 

BYTE

 

 

F / V

 

 

Decription

 

 

 

 

0-1

 

 

X

 

 

Revision code

 

 

 

 

2-361

 

 

X

 

 

Vendor specific

 

 

 

 

362

 

 

V

 

 

Off line data collection status

 

 

 

 

363

 

 

X

 

 

Self-test execution status byte

 

 

 

 

364-365

 

 

V

 

 

Total time in seconds to complete off-line data collection activity

 

 

 

 

366

 

 

X

 

 

Vendor specific

 

 

 

 

367

 

 

F

 

 

Off-line data collection capability

 

 

 

 

368-369

 

 

F

 

 

SMART capability

 

 

 

 

 

 

 

 

 

 

Error logging capability

 

 

 

 

370

 

 

F

 

 

7-1 Reserved

 

 

 

 

 

 

 

 

0 1=Device error logging supported

 

 

 

 

 

 

 

 

 

 

 

 

 

 

371

 

 

X

 

 

Vendor specific

 

 

 

 

372

 

 

F

 

 

Short self-test routine recommended polling time (in minutes)

 

 

 

 

373

 

 

F

 

 

Extended self-test routine recommended polling time (in minutes)

 

 

 

 

374

 

 

F

 

 

Conveyance self-test routine recommended polling time (in minutes)

 

 

 

 

375-385

 

 

R

 

 

Reserved

 

 

 

 

386-395

 

 

F

 

 

Date Code

 

 

 

 

396

 

 

V

 

 

Number of MU in device (0~n)

 

 

 

 

397+(n*6)

 

 

V

 

 

MU number

 

 

 

 

398+(n*6)

 

 

V

 

 

MU data block

 

 

 

 

400+(n*6)

 

 

V

 

 

MU spare block

 

 

 

 

401+(n*6)

 

 

V

 

 

Init. Bad block

 

 

 

 

402+(n*6)

 

 

V

 

 

Last Defect Bad block ( Newest state)

 

 

 

 

511

 

 

V

 

 

Data structure checksum

 

 

F=the content of the byte is fixed and does not change.

V=the content of the byte is variable and may change depending on the state of the device or

the commands executed by the device.

X=the content of the byte is vendor specific and may be fixed or variable.

R=the content of the byte is reserved and shall be zero.

* 4 Byte value : [MSB] [2] [1] [LSB]

Above technical information is based on CFA standard data and tested to be reliable. However, Transcend makes no warranty, either expressed or implied, as to its accuracy and assumes no liability in connection with the use of this product. Transcend reserves the right to make changes in specifications at any time without prior notice.