Transition Networks Installing Model 1004 Repeater Hub, BNC Connector/10Base2 Connection

Models: 1004

1 12
Download 12 pages 36.5 Kb
Page 12
Image 12
Installing Model 1004 Repeater Hub

Installing Model 1004 Repeater Hub

NOTE: Rackmount screws and clip nuts are NOT provided with the Model 1004 Repeater Hub.

To install the Model 1004 Repeater Hub in 19-inch rack cabinet:

T R A NConnecting Cable to SIC/RJ-45 Connectors SBNC Connector/10Base2 ConnectionManual background I T I O N

1

2

3

4

5

6

7

8

9

10

11

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Locate four (4) screws (and clip nuts, if necessary) for each Model 1004 Repeater Hub to be installed.

2.Carefully align the Model 1004 Repeater Hub between the 19- inch rack mounting rails at the installation position.

3.Install two screws through right front bracket and two screws through left front bracket, using clip nuts if necessary.

To install the Model 1004 Repeater on table or other flat surface:

1.Carefully turn Model 1004 Repeater Hub to side.

2.Install four (4) rubber feet (provided with repeater hub):

Remove protective paper from adhesive surface of rubber foot.

Position rubber foot at bottom corner of repeater hub.

Secure rubber foot to repeater hub surface.

Repeat for remaining rubber feet.

3.Return Model 1004 Repeater Hub to upright position.

Connecting Cable to SIC/RJ-45 Connectors

Connections between installed Model 1004 Repeater Hub SICs or between a Model 1004 Repeater Hub SIC and a hub or terminal device include:

Female AUI Connector/10Base5

Male AUI Connector/PC

RJ Connector/10BaseT

BNC Connector/10Base2

ST Connector/Fiber Optic

BNC Connector/10Base2 Connection

The thinnet coaxial card (E-CX-SIC) provides a BNC connector to 10Base2.

NOTE: Verify that coax cables on Model 1004 Repeater Hub are terminated properly at both ends.

 

50 ohm terminator

(In a coax thinnet

 

 

 

 

 

 

 

 

 

 

 

 

installation, the first and

 

 

 

 

 

 

 

 

 

 

 

 

last device in a daisy-chain

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

must be terminated with a

 

 

 

 

 

 

50 ohm terminator.)

 

 

 

 

 

 

Additionally, the 10Base2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

segment must be grounded

 

 

 

 

 

 

to “earth ground” at one

 

 

 

 

 

 

end.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50 ohm terminator

9

Model 1004

12-Port Ethernet™ Repeater Hub

10

Page 12
Image 12
Transition Networks specifications Installing Model 1004 Repeater Hub, Connecting Cable to SIC/RJ-45 Connectors