ETHERNET CABLE SPECIFICATIONS
Maximum number of terminal devices on Ethernet network: | 1024 |
|
|
10Base5 Cable and Connector Specifications
The physical characteristics of the 10Base5 cable must meet or exceed IEEE 802.3 10Base5 specifications.
10Base5 Cable Characteristics:
Cable type: | RG8 Solid Coaxial (ThickNet) |
Impedance: | 50 Ω @ 10 MHz |
Capacitance: | 26pF/ft |
Maximum Cable Length: | 500 meters (1650 feet) |
Maximum number network connections: | 100 |
Minimum distance between connections: | 2.5 meters (8.2 feet) |
Terminate 10Base5 cable at one end using a 50 ohm terminator and at the other end using a 50 ohm terminator grounded to earth ground.
AUI Cable and Connector Specifications
The cable is a special
Maximum AUI Cable Length: |
| 50 meters (165 feet) | ||||
AUI Connector Characteristics: |
|
|
|
| ||
AUI Port: | Male |
|
| |||
AUI Connection: | Cable shell must be grounded. |
|
| |||
Connector Legend: | 1 Logic Ref. | 6 | Power Return | 11 Logic Ref | ||
| 2 | Collision+ | 7 | N/C | 12 | Receive |
| 3 | Transmit+ | 8 | Logic Ref. | 13 | Power |
| 4 | Logic Ref. | 9 | 14 | Logic Ref. | |
| 5 | Receive+ | 10 Transmit- | 15 | N/C |
10BaseFL Cable and Connector Specifications
The physical characteristics of the 10BaseFL cable must meet or exceed IEEE
802.310BaseFL specifications.
10BaseFL Cable Characteristics:
Fiber Optic Cable Recommended: | 62.5/125 µm multimode fiber | |
Optional: | 100/140 µm multimode fiber | |
| 85/125 µm multimode fiber | |
| 50/125 µm multimode fiber | |
Fiber Optic Transmitter Power: | Average power: | |
| Peak power: | |
Fiber Optic Receiver Sensitivity: | Average sensitivity: | |
| Bit error rate: | ≤ |
Maximum Cable Length: | 2000 meters (6500 feet) |
10BaseFL Connector Characteristics:
ST type connectors (SMA type available upon request)
Table of Contents
1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . 1
The Model 1004 Repeater Hub . . . . . . . . . . . . . . . . . . . . . . .1
Model 1004 Repeater Hub Features . . . . . . . . . . . . . . . . . . . . .1 Networking the Model 1004 Repeater Hub . . . . . . . . . . . . . . . .2
Model 1004 Repeater Hub Connectors, Indicators,
and Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2 SITE CONSIDERATIONS. . . . . . . . . . . . . . . . . . . . 4
Ensuring Correct Segment Number . . . . . . . . . . . . . . . . . . . .5 Ensuring Correct 10BaseT Configuration . . . . . . . . . . . . . . . .8
3 INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Unpacking the Model 1004 Repeater Hub | . .7 |
Installing | . .8 |
Installing Model 1004 Repeater Hub | . .9 |
Connecting Cable to SIC and | r10 |
BNC Connector/10Base2 Connection . . . . . . . . . . . . . . . . . . .10 Twisted Pair Connector/10BaseT Connection . . . . . . . . . . . . .11 Female AUConnector/10Base5 or Transceiver Connection . . .12 Male AUIConnector/PC Connection . . . . . . . . . . . . . . . . . . . .13 Fiber OpticConnector/10BaseFL Connection . . . . . . . . . . . . . .13
Connecting Power to Model 1004 Repeater | 14 |
4 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Monitoring Power LED . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Monitoring Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
5 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . 16
Fault Isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Technical Support Contact . . . . . . . . . . . . . . . . . . . . . . . . .16
WARRANTY STATEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 ETHERNET CABLE SPECIFICATIONS . . . . . . . . . . . . . . . . . . 19 MODEL 1004
19 | Model 1004 | i |