CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den
Compliance Information
UL Listed
CISPR/EN55022 Class A
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Copyright Restrictions
10BASE-2 Cable Specifications
The physical characteristics of the
Cable Characteristics:
Cable type: | Stranded Coaxial RG58 (ThinNet) | |
Impedance: | 50 Ω @ 10 MHz |
|
Mutual Capacitance: | 24 pF/ft ±20% @ 10 | MHz |
Maximum Cable Length: | 185 meters (610 feet) | |
Maximum number network connections: | 30 |
|
Minimum distance between connections: | 0.5 meters (1.6 feet) |
|
Terminate
10BASE-T Cable and Connector Specifications
The physical characteristics of the
802.3
10BASE-T Cable Characteristics:
Category 3 wire or better is required; category 5 wire is recommended. Either shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.
Category 3: |
|
Gauge | 24 to 22 AWG |
Attenuation | 28 dB/1000’ @ 10 MHz |
Differential Characteristic Impedance | 100 Ω ±10% @ 10 MHz |
Category 5: |
|
Gauge | 24 to 22 AWG |
Attenuation | 20 dB/1000’ @ 10 MHz |
Differential Characteristic Impedance | 100 Ω ±10% @ 10 MHz |
Maximum Cable Length: | 100 meters (330 feet) |
10BASE-T Connector Characteristics:
The two active pairs in a
&white/orange) for the active pins.
© 1997 TRANSITION Networks.
All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Trademark Notice
Twisted Pair #1
Twisted Pair #2
Straight Through Cable
11
22
33
66
Twisted Pair #1
Twisted Pair #2
Crossover Cable
11
22
33
66
All registered trademarks and trademarks are the property of their respective owners.
Connectors for unlike devices | Connectors for like devices |
LANMaster™ T8 |
| 20 |