VII. OPERATING THE BLAST CHILL CONTROL (cont’d)
VII. j - CONTROL PANEL CONFIGURATION: INTRODUCTION - The Traulsen Blast Chiller Unit is preset and tested at the factory to be fully functional using default settings programmed into the unit. Therefore, it is advised that the following procedures should be performed by an experienced blast chill op- erator, or an approved blast chill technician.
STEP 1: Start configuration by pressing the “T” on the Traulsen logo (see figure 34). The display will show U1A, which is the maintenance air temperature, 34- 38°F is typical during operation. Press the “T” again, now U1E1 is displayed. This displays the current main- tenance evaporator coil temperature. Press again, no- tice U1E2 is displayed. This displays current chill evaporator coil temperature. Press again, and notice the “F” for Fahrenheit begins to flash next to the dis- play screen. You have now accessed the first set func- tion. Using the UP/DOWN arrows, you can change the settings for Fahrenheit to Celsius (F° to C°, see figure 35).
Press “T” on logo to start configuration and unlock.
STEP 5: The display shows the temperature flashing. This is the cut out air temperature of the maintenance mode. Using the UP/DOWN arrows, adjust setting from 37°F to 41°F
STEP 6: Press ENTER.
STEP 7: The word “BLAST” is flashing above the SOFT/ FLASH button. Using the UP/DOWN arrows, adjust the temperature range in the display from 35°F to 41°F
STEP 8: Press ENTER.
STEP 9: The word “FLASH” is flashing above the SOFT/ FLASH button. Using the UP/DOWN arrows, adjust the temperature range in the display from 0°F to 5°F
STEP 10: Press ENTER.
STEP 11: “H” will display on the screen. UP/DOWN arrows will change solid display to flashing “H” dis- play and back.
Solid “H” = Normal factory setting to support a HACCP operating mode.
Flashing “H” = Allows Continuous Batching mode of operation. See Continuous Batching for Blast Chill and Flash Chill Modes (cannot be used with Soft Chill, see figure 36).
Fig. 34
STEP 2: Press ENTER.
STEP 3: The display shows the temperature flashing. This is the cut out air temperature of the maintenance mode. Using the UP/DOWN arrows, adjust setting from 30°F to 34°F
STEP 4: Press ENTER.
Fahrenheit
Fig. 35
Fig. 36
STEP 12: Press ENTER.
STEP 13: Number 1,2 or 3 will appear on the screen. use the UP/DOWN arrows to select the desired num- ber of Printed Batch Data copies.
STEP 14: Press ENTER. This completes the control panel configuration process. The unit is now ready for operation.