Traulsen RBC50 Food Probe Failure Warning, Chill Cycle Batch Over 6 Hours, Refrigeration Failure

Models: RBC100 RBC200 & RBC400 RBC50 RBC50, RBC100, RBC200, RBC400, RBC200RT, RBC400RT

1 28
Download 28 pages 43.39 Kb
Page 20
Image 20

VIII. UNDERSTANDING PRINTOUTS (contd)

VIII.e - FOOD PROBE FAILURE WARNINGS:

FOOD PROBE FAILURE WARNING:

Alarm occurs only during a programmed batch.

Failed Food Probe

Unit Number Location of Failed Probe

Alarm Date & Time

Employee Number

Batch Number

CHILL CYCLE BATCH OVER 6 HOURS:

Alarm occurs when a programmed batch runs for more than 6 hours. The chill cycle will continue to run until complete or cancelled/

6-Hour Batch Warning Notification

Alarm Date & Time

REFRIGERATION FAILURE:

Alarm occurs when interior temperature remains over 100°F (37.8°C) for more than 20 minutes. CAUTION: The blast chill unit will shut down and requires power OFF and then back ON to reset normal operation (reset button will not work).

Unit Number With Refrigeration Failure

Refrigeration Failure Over Temperature Warning

Alarm Date & Time

POWER LOSS NOTIFICATION:

Alarm occurs as a result of a power loss, immediately after power is restored.

Power Loss Warning

NOTES: Days

Hours

Minutes

Power Loss

Date & Time

Power Is Restored

Date & Time