CONNECTING TO THE MAINS TERMINAL

CONNECTING TO THE MAINS TERMINAL

lWarning: This cooker must be earthed.

Make connection as shown in Fig. 6 by proceeding as follows:-

Earth (Green or

 

 

 

 

Red or

Green/Yellow)

 

 

 

 

Brown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blue or

 

 

 

 

 

 

Black

 

 

 

 

 

 

 

 

 

 

 

 

 

5mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Earth Tab

 

 

 

Mains

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable

 

 

 

Fig.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Preform wires to the appropriate shape to suit fitting into the mains terminal block.

Strip inner insulation on wires using wirestrippers.

Twist the bared wires using pliers.

Cut bared wires 10mm away from the end of the inner insulation. Where uninsulated Earth wires are used ensure they are suitably sheathed to leave 10mm bare wire to fit into the terminal.

Clamp bare wires into the relevant terminal and check they are held by tugging each one in turn.

Clamp the mains cable securely ensuring 5mm of the outer insulation is inside the terminal block and that the wires are not taught but not so slack

las to cause any fouling. See Fig. 6.

Place fuse/ miniature circuit breaker in circuit and switch on at mains.

CONNECTING TO A HOB OR COOKER POINT

lWarning: This cooker must be earthed.

Either follow in general terms the instructions for connecting to the terminal block or refer to the hob suppliers installation instructions.

Feed the cable through the cabinet and arrange to route the cable away from the cooker which may become hot.

CHECKING ELECTRICAL CONNECTIONS

Confirm the cooker is correctly connected by switching on and observing the various oven

lfunctions indicators.

The electronic timer will flash on and off.

NOTE: HOUSE CIRCUIT

Earth leakage and continuity tests must be carried out before the cooker is connected to the mains supply and re-checked after fitting.