Tricity Bendix SG211X manual Replace the nozzles of the hob burners, Hob burners, no air, correct

Models: SG211X

1 32
Download 32 pages 6.3 Kb
Page 26
Image 26
Replace the nozzles of the hob burners

Replace the nozzles of the hob burners

Before any modifications or conversion to a kind of different gas, you must DISCONNECT the cooker from the electricity supply and ensure that all control knobs are in the OFF position, and the appliance has cooled completely.

 Hob burners Hob burners

Remove the pan supports;

Remove the caps and the burner crowns;

Using a No 7 socket spanner unscrew the nozzles and replace them with those required for the type of gas in use (see table no. 1).

Reassemble the parts following the same procedure in reverse.

These burners do not need any primary air regulation.

Adjustment of minimum level for the hob burners

The burner is correctly adjusted when the flame is stable silent and goes out without any noise. When changing the type of gas check that the minimum level is correct. The air admission is correct when the flame is about 4 mm in length.

26

The top burners do not need adjustment of primary air.

Check that, turning the knob quickly from the maximum position to the minimum one, the flame does not go out.

no air

correct

excess of

adjustment

air

Adjustment of minimum level for the hob burnersHob burners

To adjust the minimum level:

Light the burner

Turn the knob to the position of the minimum flame;

Remove the knob;

Unscrew or screw the by-pass screw (on the right above of tap shaft) until a regular small flame is reached.

For LPG screw completely the by-pass screw.

Reassemble the parts following the same procedure in reverse.

Check that, when turning the knob quickly from the maximum position to the minimum one, the flame does not go out.

Page 26
Image 26
Tricity Bendix SG211X Replace the nozzles of the hob burners, Hob burners, Adjustment of minimum level for the hob burners