Adjustment of minimum level

Adjustment of minimum level

Manual backgroundOven burner

Remove the top pan support as well as the burner caps and the burner crowns.

Unscrew and remove the 2 top plate-fixing screws and remove the top plate.

Light the burner knob on position 9 and leave the oven door closed for about 10 min.

Turn the knob slowly to position 1.

Pull off the knob to adjust minimum flow.

Unscrew or screw the by-pass screw (is it above of tap shaft) until a regular small flame is reached.

For LPG, adjust the by-pass screw for minimum flame setting.

The flame shouldn’t extinguish when closing the oven door.

Grill burner

The grill temperature cannot be adjusted. To obtain a lower temperature or slower cooking time the grill pan must be lowered away from the flame.

Manual background After completion of any repairs, conversion or adjustments, the statutory safety tests must be carried out.