23
CONVERSION OF GAS
Your cooker is designed to work with natural gas,
and is convertible for use with propane or butane.
The LPG conversion kit is available from your
Service Force Centre and must be fitted by a
Registered engineer/ competent person.
For changing the gas type it is necessary to:
replace the nozzles (hob, oven and grill);
adjust the minimum level (hob and oven);
adjust the primary air (oven and grill);
check the gas connection;
Stick the label supplied with the
replacement nozzles (from the Service Force
Centre) corresponding to the gas type utilized.
SPECIFICATION NOZZLES
Table no.1
(Cat : II 2H3+)
Cons
Burner Normal
power
(kW)
Simmer
power
(kW)
By-
pass
(mm) Gas Type Pressure
(mbar)
Nozzle
diameter
(mm) m3/h g/h
RAPID 2.60 0.72 0.42
Natural Gas
Butane
Propane
20
28-30
37
1.12
0,86
0,86
0.248
-
-
-
189,05
185,68
SEMI-
RAPID 2.00 0.43 0.32
Natural Gas
Butane
Propane
20
28-30
37
0.96
0,71
0,71
0.191
-
-
-
145,43
142,83
AUXILIARY 1.00 0.35 0.29
Natural Gas
Butane
Propane
20
28-30
37
0.70
0,50
0,50
0.093 -
72,71
71,41
OVEN 3.20 1.00 0.46
Natural Gas
Butane
Propane
20
28-30
37
1.30
0,88
0,88
0.305
-
-
-
232,68
228,52
GRILL 2.50 - -
Natural Gas
Butane
Propane
20
28-30
37
1,15
0,80
0,80
0,238
-
-
-
181,78
178,53